Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T08BU02086
Parcel: 115042370

Address:
1227 N 3RD AV

Review Status: Completed

Review Details: WALLS ZONING/ENGINE

Permit Number - T08BU02086
Review Name: WALLS ZONING/ENGINE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/01/2008 MICHAEL ST. PAUL ZONING REVIEW Approved
12/01/2008 BIANCA RAMIREZ ENGINEERING REVIEW Approved December 1, 2008
FLOODPLAIN USE PERMIT # T08OT02822
PROJECT ADDRESS: 1227 N 3rd Avenue
APPLICANT'S NAME: William Ford
PROPERTY OWNER: William Ford


This parcel is impacted by a City of Tucson 100-year floodplain (Mable Street Wash by JE Fuller). The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:

1227 N 3rd Avenue, Tucson, AZ 85705, FELDMANS AMENDED LOT 10 BLK 15 (9786/1294 1297 1299 7 1300). In a portion of Township 14 South, Range 13 East, Section 1, for the construction of 50 LF of a 6' CMU wall and 25LF of a 4'-5' CMU wall.


The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) This parcel is impacted by a City of Tucson 100-year floodplain (Mable Street Wash by JE Fuller). Therefore, the proposed development is subject to special requirements:

A) The walls are to be constructed in a manner to prevent flotation, collapse and lateral movement.
B) Walls are to be constructed as per plan submitted by William Ford (RA) dated 11-3008. Indicating that openings that are 8X8X16 will be provided at grade level - 10' on center.

3) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T08OT02822 FOR INFORMATION PLEASE CALL 791-5550."

4) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.

5) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

6) See the associated activity T08BU02086.


This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 12 Day: 1 Year: 2009

APPLICANT: William Ford
ADDRESS: 1227 N 3rd Avenue, Tucson, AZ 85705
PHONE: (520) 623-0364
OWNER: Same as Above
ADDRESS:
PHONE:


SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.