Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T08BU02021
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/16/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: January 16, 2008 SUBJECT: Grading Plan TO: a.s.i. architect LOCATION: 1447 E Blacklidge Rd, T13S, R14E, Section 31, Ward 3 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T08BU02021 (Second Review) RESUBMITTAL REQUIRED: Grading Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan for the above referenced property. Engineering Division does not recommend approval of the grading plan at this time. Please address the following review comments prior to the next submittal. Provide a response letter to the comments along with the corrected copies of the site plan. Grading Plan: 1. Complied 2. Proposed roof drainage patterns indicated and scuppers identified. However, scupper detail does not show standard type 1 scupper, please clarify. 3. Complied. 4. Cut or fill slopes require a 2' minimum setback from property line. Proposed screen walls are to be offset from property line a minimum of 2'. The wall located along north property line does not appear to be meeting 2' setback requirement. 5. Drainage patterns are to remain - demonstrate that proposed development maintains current drainage patterns. Proposed design appears to be concentrating flow in post development. Verify that drainage patters are maintained and that design will not cause inverse impact to property receiving concentrated flow. 6. Provide flow arrows, grades and flow rates within and adjacent to site to show drainage scheme and to demonstrate that existing conditions and future conditions match. Show elevations of adjacent properties or at a minimum spot elevations. Per site visit 1/15/09 flow will be exiting into adjacent north property. Provide spot elevations and demonstrate positive flow to Hedrick Drive. 7. Complied 8. Grading limits should not include the 2' setback from property line. Please revise accordingly. 9. Complied 10. Provide existing and proposed grades for northeastern propty lines and southeasternly propery lines. Along outer side of sidewalk along northeasternly property line and along southeasternly property line show grades and minimum 2' setback from property lines. 11. Not required - suggestion 12. Complied 13. Additional comments per site visit 1/15/09: A. Show positive flow on north property - topo per Mapguide is showing that there is no positive flow. However, site is developed. As built elevations needed for further review. Show elevations of parking lot for 1488 E Hendrick. In addition, label openings in wall on grading plan. B. Label wall openings in existing wall and provide scuppers for adjacent sidewalks. 14. Additional comments may be forthcoming. Drainage report: 1. Please include a response letter to the comments along with the corrected copies of the DR. 2. Complied 3. Complied 4. Complied 5. Complied 6. Provide revised copy of the drainage report and geotechnical report with grading submittal for review. Note: Geotechnical report was not submitted. Provide two copies of geotechnical report with next submittal. 7. Additional comments per site visit 1/15/09. A. Revise Drainage Report to include discussion and any necessary information needed to demonstrate positive flow of north property - 1488 E Hendrick from the outlet. It appears that adjacent property could possible be higher in elevation that the weir outlet, so please clarify. 8. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 01/20/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | January 20, 2009 Development Services Department Zoning Review Section Michael St.Paul Planning Technician T08BU02021 Grading Plans for T08CM02820 1447 East Blacklidge Drive Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. We cannot verify that the grading plan is in compliance with a site plan for this site. Please submit two copies of the last approved and stamped Site Plan, Landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming. |
| 01/21/2009 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit a copy of the approved site and landscape plans for reference. The grading application will be reviewed for compliance when the approved documents are included in the submittal. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/26/2009 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 01/26/2009 | SUE REEVES | REJECT SHELF | Completed |