Permit Number: T08BU02004
Parcel: 11917013H

Address:
3502 S 6TH AV

Review Status: Completed

Review Details: REVISION - GRADING

Permit Number - T08BU02004
Review Name: REVISION - GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/01/2011 STEVE SHIELDS ZONING REVIEW Needs Review
03/07/2011 LOREN MAKUS ENGINEERING REVIEW Needs Review March 7, 2011
T07CM01474
T08BU02004
Revised site and grading plans

The revisions to the site and grading plans cannot be approved as submitted.

1. A revised drainage report demonstrating balanced basin detention is required. Until the drainage report is reviewed and approved, additional site and grading plan comments should be expected. The site and grading plans must be revised as necessary to provide for adequate detention.
2. The actual physical location and extent of the water lines and other utilities must be presented on the site plan, especially if their location impacts the detention or water harvesting facilities.
3. The site and grading plans must show enough grade date to demonstrate the functionality of the water harvesting areas along the east property line. Provide sections through the boundaries to show how the grades will be achieved.
4. Show the locations of electrical service boxes associated with the street lights as well as any other right-of-way facilities that might affect the project.

Loren Makus, EIT
loren.makus@tucsonaz.gov
03/11/2011 ANDREW CONNOR NPPO REVIEW Denied Ensure that all Engineering comments and concerns are addressed prior to landscape / NPP approval.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/04/2011 CINDY AGUILAR OUT TO CUSTOMER Completed
04/04/2011 SUE REEVES REJECT SHELF Completed