Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T08BU01954
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/09/2009 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | DATE: January 9, 2009 TO: DOWL Engineers SUBJECT: Bldgs #1, 2, & 3 for Riverfront Plaza (S07-101) Phase 2 Grading Plan Review LOCATION: T14S R13E Section 35, 119-42-009C REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: T08BU01954 SUMMARY: The associated Grading Plans for Buildings #1, 2, & 3 for Pads 2, 3, & 4, copy of the approved Tentative Plat/Development Plan, one copy of the approved grading plans, were reviewed by Engineering. Engineering has reviewed the associated grading for sheets C2.0, C3.0, C4.0, & C4.1 and does not recommend approval of the grading plan at this time. GRADING PERMIT COMMENTS: 1) If remaining 3 pads are not to be graded to FPE and developed for a building construction, then show permanent control for erosion stabilization for each pad, on planview or with details/notes. 2) On sheet C3.0, address the following comments: a) Provide as-built spot elevations on rear side of north wall. 3) Assure all items listed in the punchlist for T08BU00687 have been completed. Specifically, the following will be inspected: a) Discharge area for rear swale constructed to outfall to the north. b) Basin, for visual percolation. 4) Basin showed virtually little to no percolation from rain event ending 5JAN09. Basin function must be achieved prior to final approval of this grading plan. Obtain EOR recommendations for mitigating basin infiltration issues. Dry wells and scarification will not be accepted. Propose remediation measures and discuss with DSD Engineering Reviewer. 5) Provide DSMR for dumpster per Environmental Services for the Buffalo Wings dumpster enclosure. 6) Assure any remaining fees are paid. 7) On sheet C4.0 address the following comments: a) For section detail A, clarify 50-ft W.A.S.H. Study Area. 8) Label DSMR reference for detail 16 on sheet C4.1. Resubmit with response letter, 2 copies of plans and one copy of approved grading plan and one copy of approved Tentative Plat / Development Plan. If you have any questions, please call me at 837-4934. Elizabeth Leibold, PE Civil Engineer Engineering Division Development Services |
01/12/2009 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
12/29/2008 | DAVID RIVERA | ZONING | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/05/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
06/05/2009 | SUE REEVES | REJECT SHELF | Completed |