Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T08BU01561
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/22/2008 | JASON GREEN | ENGINEERING | REVIEW | Approv-Cond | DATE: September 22, 2008 SUBJECT: Shops at Midvale Grading Plan- 2nd Engineering Review TO: The WLB Group ATTN: Andie Haslem LOCATION: T15S R13E Sec15, Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: T08BU01561 (Grading Plan) SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan (T08BU01561), Drainage Report (The WLB Group, Inc., 09JUL08), Geotechnical Engineering Report (LMT Engineering, Inc., 23APR08 with addendum 02SEP08), Stormwater Pollution Prevention Plan (The WLB Group Inc., 12AUG08 revised 12SEP08) and Floodplain Use Permit (T08OT02019) for the above referenced property. Engineering Division recommends conditional approval of the grading plan application at this time. " The Grading Plan has been conditionally approved by the Engineering Division, however until the Tentative Plat is approved through the CDRC office Development Services will not provide the final approval to the Grading Plan or any future Building Plans or Grading Plans. Please refer to comments from Patricia Gehlen for all comments and requirements for the Tentative Plat approval. For any questions I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
| 09/22/2008 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | September 22, 2008 Development Services Department Zoning Review Section Michael St.Paul Planning Technician T08BU01561 Grading Plans for S08-043 Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved tentative plat. Please submit one copy of the CDRC approved and stamped tentative plat, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the CDRC approved and stamped tentative plat. Additional comments may be forthcoming. |
| 09/22/2008 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit a copy of the approved development plan including landscape and native plant preservation plans for reference. The grading application will be reviewed for complianc when the approved documents are included in the submittal. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/29/2008 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 09/29/2008 | SUE REEVES | REJECT SHELF | Completed |