Review Status: Completed
Review Details: GRADING
Permit Number - T08BU01469
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/27/2008 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | To: Swain and Associates, LTD DATE: August 27, 2008 7350 E. Speedway Blvd., Ste. 210 Tucson, Arizona 85710 SUBJECT: Ricon Vista Middle School, 10770 E. Bilby Rd. Site plan - (First Review) T15S, R15E, Section 12 RESUBMITTAL REQUIRED: Site Plan and Hydrology Report. The Site Plan (SP) and Hydrology Report (HR) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. 3. Please provide property description per D.S. 2-02.2.1.3. 4. Please label lot dimensions and bearings per D.S. 2-02.2.1.5 5. Provide all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6. 6. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 7. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 8. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. 9. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. 10. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15. 11. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. 12. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. 13. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. 14. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 15. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the SP. 16. Sidewalks, curbs and wheelchair ramps are required where applicable per D.S. 3-01.3.0 and installed with "Detectable Warnings" per ADAAG. 17. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 18. Location and orientation of existing major physical features, such as railroad tracks and drainageways per D.S. 2-02.2.1.22. 19. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. 20. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27. 21. Show Development plan number on all sheets per D.S. 2-02.2.1.29. 22. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. 23. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please address. 24. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 25. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable. 26. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice. 27. List the consulting engineer and the owner/developer on the plans with the pertinent information. 28. A floodplain use permit is required. 29. Add note: "Depress all landscaped areas 6" maximum for water harvesting". 30. A Stormwater pollution prevention plan (SWPPP) is required during Grading plan submittal. See SWPPP requirements listed below. Contact Paul P. Machado at 791-5550 x1193. 31. "A grading permit and Stormwater Pollution Prevention Plans (SWPPP's) will be required for this project. Submit 3 sets of grading and SWPPP's with text, upon completion and submittal of a grading permit application. A grading permit may not be issued prior to site plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the plans". Hydrology Report: 1. Please include a response letter to the comments along with the corrected copies of the HR. 2. A Hydrology report is required for parcels affected by 100 year flows of 100 cfs, of more per S.M.D.D.F.M., chap. II, 2.1.2, therefore the drainage study report is not acceptable. 3. The content and format of the Hydrology report should follow S.M.D.D.F.M., chap. II, 2.1.3. 4. Show the project address on the cover of the Hydrology report. 5. Add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DR. See example attachment. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/10770 E. Bilby Rd_grad |
| 08/27/2008 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | All comments have been met. Vail school district and architect will agree on grates for drainage pipes. PM. 9-9-8. |
| 09/08/2008 | ANDREW CONNOR | NPPO | REVIEW | Passed |