Permit Number: T08BU01458
Parcel: 107020240

Review Status: Completed

Review Details: GRADING

Permit Number - T08BU01458
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/27/2008 TERRY STEVENS ZONING REVIEW Denied Grading notes for permits plus.
With SITE PLAN

08/28/2008

Development Services Department
Zoning Review Section

Terry Stevens
Lead Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.
09/02/2008 ANDREW CONNOR NPPO REVIEW Denied Site plan approval is necessary to continue review.
09/18/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: August 24, 2008
SUBJECT: Grading
TO: MPE
LOCATION: 3231 N Freeway Industrial Loop, T14S, R15E, Section 6, Ward 2
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T08CM01458 (First Review)


RESUBMITTAL REQUIRED: Site Plan, Drainage Report

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan for the above referenced property. Engineering Division does not recommend approval of the grading plan at this time. Please address the following review comments prior to the next submittal.

Site Plan:

RESUBMITTAL REQUIRED: Grading Plan, Drainage Report

The Grading Plan (GP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Please include a response letter to the comments along with the corrected copies of the GP.

Grading Plan:

1. Grading plan clearly marked "GRADING PLAN".
2. Add the following note to the grading plan notes:
" "The approved Grading Plan is the only acceptable construction plan onsite. The Contractor may not use any other plans, such as the approved Tentative Plat and/or Development Plan, for construction purposes. The Contractor may ask the Development Services Inspector to consult with the other approved plans for additional information or details that might not be included on the approved grading plan but needed for completion of work."
3. Provide the grading activity number on each sheet in the lower right hand corner of each sheet.
4. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, add a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed.
5. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
6. Call out exiting and future peak discharges entering and exiting the site.
7. Additional comments may be forthcoming.
8. Provide Finished Floor Elevation for building on grading plan.
9. Revise handicap sign to read $532 FINE
10. Provide oil and water separator for dock loading.
11. Indicate scupper in North West corner of parcel.
12. Provide grading plan number in the lower right hand corner of each sheet.
13. Provide Drainage Engineer information on grading plan for future reference.
14. Additional comments may be forthcoming.

Drainage Report - Approved
.
If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Bianca Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax

Final Status

Task End Date Reviewer's Name Type of Review Description
10/01/2008 CPIERCE1 OUT TO CUSTOMER Completed
10/01/2008 SUE REEVES REJECT SHELF Completed