Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T08BU01201
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/19/2008 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | November 21, 2008 T08BU01201 Grading Permit Review El Rio Health Center SE Clinic The Grading Permit cannot be approved at this time. The Development Plan must be approved before the grading plan can be approved. The Drainage Report and Stormwater Pollution Prevention plans are accepted for this project. Based on the comments on the previous review, vertical curb was replaced with headers at all parking islands. The Land Use Code requires landscape islands to be protected from vehicular traffic with a physical barrier. The usual configuration is vertical curb with limited areas of depressed curb. Other barriers are also acceptable. Once the development plan has been fully approved and signed by the CDRC manager, please re-submit the grading permit application with the associate documents. Ensure that any required changes to the grading plan that may be required by the approved Development Plan are reflected in the revised plans. If you have any questions, or if you wish to set up a meeting please contact me at loren.makus@tucsonaz.gov. |
| 11/24/2008 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | November 24, 2008 Development Services Department Zoning Review Section Michael St.Paul Planning Technician T08BU01201 Grading Plans for D08-0007 (2nd review) 6950 East Golf Links Road Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. The Development Plan has not been approved. Please submit two copies of the approved and stamped Development Plan, Landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming. |
| 11/25/2008 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit a copy of the approved development plan including landscape and native plant preservation plans for reference. The grading application will be reviewed for compliance when the approved documents are included in the submittal. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/04/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 12/04/2008 | SUE REEVES | REJECT SHELF | Completed |