Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T08BU00435
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/11/2008 | ANDREW CONNOR | NPPO | REVIEW | Denied | Site plan approval is necessary to continue review. Revise grading documents as necessary to comply with the approved plans. |
| 03/21/2008 | TERRY STEVENS | ZONING | REVIEW | Denied | 03/21/2008 Development Services Department Zoning Review Section Terry Stevens Lead Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. |
| 04/22/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | To: DCC Company DATE: April 16, 2008 2828 N Country Club, Suite 100 FROM: Bianca Ramirez, CFM Tucson, Arizona 85716 Engineering Division SUBJECT: Private Paving Grading and Drainage Plan for Living Spaces - Fort Lowell 1937 E Fort Lowell Rd, Tucson, Arizona 85719 Grading Plan T08BU00435 (First Review) T14S, R14E, Section 29 RESUBMITTAL REQUIRED: Grading Plan and Drainage Report The Grading Plan (GP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Include a response letter to the comments along with the corrected copies of the grading plan. Grading Plan: 1. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. 2. Indicate on the site plan and in details that all handicap access ramps at crosswalks or at the transition of a pedestrian circulation area to a vehicular use area have required detectable warning devices (truncated domes) in the correct location. Truncated domes along Fort Lowell should be at the edge of sidewalk. 3. Revise keynote # 26 note to read: "Depress all landscaped areas a maximum of 6" for water harvesting." 4. Add the following notes to the grading plan notes: " "The approved Grading Plan is the only acceptable construction plan onsite. The Contractor may not use any other plans, such as the approved Tentative Plat and/or Development Plan, for construction purposes. The Contractor may ask the Development Services Inspector to consult with the other approved plans for additional information or details that might not be included on the approved grading plan but needed for completion of work." 5. Show cross section with transverse and longitudinal slopes. 6. Please label the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, add a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed. 7. Dhow detail of all surface materials and call out surface paving material. 8. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 9. Call out all slopes and stabilization material (concrete, riprap, gabbions or vegetation). 10. Call out peak discharges entering and exiting the site. Provide the existing and proposed onsite to offsite 100-year discharge that is calculated and discussed in the drainage report on the plan. Label appropriately, the site plan and drainage report existing and proposed drainage locations. DS 2-02.2.1.A. 11. The drainage report shows the roof drainage directed to the south side of the building. Show downspouts and explain if there are splashpads or something being installed to erosion of channel DS 2-02.2.1.A.16. 12. A 10' street landscape border is required for this project along the street frontage. The proposed location of the trash enclosure encroaches into the border. Revise.DS 2-02.2.1.A.32. Acknowledge that comment reference email from Andy. However, email does not comment on the 10' street landscaping area. 13. Provide handicap access ramps for crossing the PAAL at the entrance of site. 14. Provide drainage arrow in legend. 15. Lable arrow located in southwest corner of site plan. See redlines for location. 16. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucson,az.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/28/2008 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 04/28/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 04/28/2008 | GERARDO BONILLA | REJECT SHELF | Completed |