Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T08BU00103
Parcel: 116292470

Review Status: Completed

Review Details: GRADING

Permit Number - T08BU00103
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/06/2008 ANDREW CONNOR NPPO REVIEW Denied Submit a copy of the approved tentative plat including landscape and native plant preservation plans for reference. The grading application will be reviewed for compliance when the approved documents are included in the submittal. Revise grading plans as necessary to comply with the approved plans.
03/14/2008 ELIZABETH EBERBACH ENGINEERING REVIEW Denied TO: Bruce Patton, PE, RICK Engineering
SUBJECT: Starr Pass Vistas Village 2 Grading Plan Engineering Review
LOCATION: T14S R13E Section 16
REVIEWER: Elizabeth Eberbach
REFERENCE: S07-033, T08SA00089
ACTIVITY NUMBER: T08BU00103

SUMMARY: The Grading Plan package was reviewed by Engineering. Engineering does not recommend approval of the Grading Plan at this time until it is in conformance with an approved tentative plat and all grading comments are addressed. The Drainage Report was reviewed for Grading Plan purposes only.

GRADING PLAN COMMENTS:
1) City of Tucson Development Standards (DS) Section No.2-03.5.2: The grading plan cannot be approved unless it is in conformance with an approved tentative plat. It is important that all Tentative Plat comments be addressed prior to resubmittal of the grading plan.
2) Provide in legend and delineate on planview with a distinct linetype the grading / disturbance limits on planview that addresses the following comments:
a) Grading / disturbance area shall include sufficient grading construction area and construction vehicles, material storage areas.
b) Includes all utility easements.
c) Includes all basin areas and the adjacent construction staging / access area.
d) Includes runout and slope grading for extents of road improvements.
e) SWPPP exhibit grading /disturbance limits shall match Grading Plan.
3) DS Sec.11-01.4.1.C: Address the following geotechnical engineering report related comments:
a) Maximum slope grade is 2:1(H:V) per geotechnical engineer. Revise the following portions of the plans to reflect maximum slope grade of 2:1(H:V):
i) Remove all reference to 1:1 MAX slopes on any sheet.
ii) Check maximum slope grade call-outs for all details on sheets 7 and 8.
iii) Label slope treatment to reflect a 2:1(H:V) to 3:1(H:V) handplaced riprap with filter fabric if not grouted.
iv) Provide call out or note that all over exposed or disturbed areas shall be treated with permanent cover per geotechnical report - revegetation. Areas where water harvesting is located, label reference to landscaping plans for hydroseeding or other revegetation.
4) Address the following drainage / floodplain related comments:
a) Provide bleed pipes on all basins due to soil types at this site, with invert elevations. For example, F/8 and planview on sheet 4 are missing invert elevations.
b) On sheets 2 and 4, dimension minimum 15-ft width of access ramps to basins.
c) DS Sec.10-01.4.3.1: Show 8:1(H:V) slopes along basin sides where human activity zones are proposed / for emergency exit and access.
d) Provide scupper for sidewalk near central basin and clarify whether scupper is provided for north basin.
e) DS Sec 10-01.1.1.2: On sheet 2, show features of multi-use design for basin.
f) Label name of Silvercroft Wash on planview sheet(s) of the grading plans.
g) Provide spot elevations along bottom of basin areas that reflect a minimum of 1% slope within basin bottom for positive drainage.
5) Address the following detail comments:
a) Add keynote call out descriptions to sheet 10.
b) Add keynote regarding: Contact Fire Department regarding application for fire box for proposed gate, enclosed with the plan package.
6) Address the following Legend comments:
a) Add disturbance/grading limits line to legend.
b) Add slope easement linetype to legend that has different linetype than grading limits.
7) DS Sec.3-01: Provide reference to PIA plans for offsite right-of-way work. On sheet 5 Castar Drive planview detail, provide complete reference to offsite improvement plans.
8) At entrances, extend curb, wedge or header between curb return at Greasewood and end of private street Sagitta Drive.
9) Show and label basis of bearing on a planview.
10) Address the following note-related comments on sheet 1:
a) Provide datum and local basis of elevation.
b) Add reference for City of Tucson grading standards to DS Sec.11-01 as a grading note to cover sheet.
c) Add to note 1 that any permission to revisions to the private streets must be obtained from the DSD Engineering Engineer and may include a revised grading plan. Call 791-5550 to discuss any revisions.
d) Add reference to DS Sec.11-01 to Grading Note 1.
e) List total cut/fill quantities and disturbance area in square-feet on sheet 1.
f) Add administrative address to plan.
g) Add grading permit application activity number T08BU00103 on the plans.
11) On sheet 1, provide / clarify general grading notes to help facilitate finalizing and inspections for the grading permit:
a) If grading construction is expected to last longer than the expiration date of the grading permit, contact DSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required.
b) Call for Pre-construction meeting. For a DSD Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at the Development Services Department, or contact DSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html
c) Any revision to the Grading Plan may require a re-submittal of a revised grading plan for review. Contact DSD Engineering at 791-5550 to discuss changes in street / grading design.
d) There shall be no disturbance or stockpiling outside of the approved Grading Limits as shown on the Grading Plan.
e) As-builts are required, with grading and basin completion documentation from project engineer at time of final inspections.
12) Delineate Grading / Disturbance Limits on planview that includes sufficient grading construction area including staging area, equipment storage, and other grading construction activities. SWPPP exhibit grading /disturbance limits shall match Grading Plan. The delineation of the grading limits must be clearly drawn on the plans for ease of use by contractor and inspector. The grading limits line should be differentiated from other linetypes and added to the legend for clarification.
13) Label dimension for toedowns for details SE, SF, SB on sheet 11.
14) DS Sec.11-01.16: To assure minimum pad elevations have been achieved, elevation as-builts for these pads may be required, prepared by a registered land surveyor prior to building permits. After pad grades are completed, submit a letter providing lot number, proposed pad elevation, and as-built pad elevation. Submit to DSD Engineering prior to building permit application for any lot adjacent to floodplain. This may be added as a note to the grading plans or added as a condition of the permit.
15) On sheet 11, clarify whether the riprap is over filter fabric or grouted.
16) On planview, riprap is located along existing flowlines that appear to be graded. Erosion protection shall be clarified on planview to not be limited to pre-developed thalweg areas but covering the inlet catch basin areas for each culvert inlet.
17) The SWPPP does not meet the minimum requirements of the AzPDES Construction General Permit (CGP). Revise the SWPPP to according to these comments:
a) Revise SWPPP exhibit to more legible scale as locations of certain SWPPP elements are not shown/legible, including CWO, TB, PT, ESM, MS, etc. Specific interim erosion/sediment controls shall be provided on the SWPP exhibit.
b) Show and label "receiving waters" on vicinity map.
c) On SWWP exhibit, indicate construction entrance at northeast entrance or show traffic control. Dimension minimum depth and minimum length (50-ft) of stabilized entrance.
d) Show limits, dimensions, and designated locations on the planview for stockpile area, concrete washout area, storage areas. These areas shall be located away from the water harvest areas, basins or washes.
e) Provide grading construction sequencing in SWPPP report.
f) Assure grading limits on SWPP exhibit match any revised limits of Grading Plan sheets.
g) Provide registrant's seal on SWPP exhibit and report.
h) Provide copy of signed, completed NOI in report.
i) Assure that the new NOI form is used, as well as signed and completed, for your project per recent ADEQ update to the CGP. The updated NOI, NOT, and Waiver Certification forms can be found at the ADEQ websites at: http://www.azdeq.gov/function/forms/appswater.html#cgp http://www.azdeq.gov/environ/water/permits/download/constnoi.pdf
j) Assure the current Construction General Permit (CGP) is included in section 19 of the SWPPP Report.
k) Update section 18 in the SWPP report to reflect City of Tucson Stormwater Ordinance not Pima County.
l) Provide registrant's seal on SWPPP exhibit and SWPP report.

Once the Tentative Plat submittal has been approved, resubmit 2 copies each of the revised grading plan and revised SWPPP, 1 copy of the revised Drainage Report, complete response letter, and a copy of the soils report with addenda. If you have any questions, please call me at 837-4934.


Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
03/26/2008 DAVID RIVERA ZONING REVIEW Denied 03/26/2008

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan at this time.

While zoning acknowledges that the grading plan is in substantial zoning compliance as it relates to the Zoning review purview, with the unapproved version of the tentative plat plan, the grading plan cannot be approved at this time.

2. Please ensure that the grading plan matches the CDRC approved and stamped tentative plat plan. Zoning will re-review the grading plan on the next submittal to ensure compliance with the CDRC approved and stamped tentative plat plan.

3. The approved and stamped tentative plat plans, landscape and NPPO plans must be included with the grading plan package on the next submittal. Two copies of each are required.

4. Label the slope for curb access ramps and draw an label the truncated domes.

5. For consistency, label the detention basin common areas as labeled on the tentative plat.

6. Please ensure that the gated entries are approved per the gated entry "Draft" standards. The minimum width of the entry gates must be 20 feet the exit gates may be 12 feet. Verify with the Fire Department's Dave Mann for minimum width requirements.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/27/2008 VFLORES1 OUT TO CUSTOMER Completed
06/27/2008 SHANAE POWELL REJECT SHELF Completed