Permit Number: T08BU00035
Parcel: 10309064B

Review Status: Completed

Review Details: GRADING

Permit Number - T08BU00035
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/18/2008 ANDREW CONNOR NPPO REVIEW Denied Submit a copy of the approved development plan including landscape plan for reference. The grading application will be reviewed for compliance when the approved documents are included in the submittal. Revise grading plan as necessary to comply with the approved plan.
02/25/2008 MICHAEL ST. PAUL ZONING REVIEW Denied February 25, 2008

Development Services Department
Zoning Review Section

Michael St.Paul
Planning Technician

T08BU00035 Grading Plans for D07-0042
3760 North Commerce Drive

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. In addition, we could not verify that the grading plan was in compliance with the approved development plan for Zoning Review. It appears that the Development Plan has been approved but the copies provided have not been approved. Please submit two copies of the approved and stamped Development Plan, Landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming.
03/07/2008 ELIZABETH EBERBACH ENGINEERING REVIEW Approved TO: Richard Macias, PE, Olsson Associates
SUBJECT: North Tucson Business Center Grading Plan Engineering submittal Review
REVIEWER: Elizabeth Eberbach
LOCATION: T13S R13E Section 28, Ward 1, FIRM panel 1619K
ACTIVITY NUMBER: T08BU00035

SUMMARY: The grading plan sheets for the proposed onsite drainage improvements for North Tucson Business Center were submitted for review. The review package included the approved revised Development Plan, Grading and Paving Plans, SWPP reports, and drainage report. Engineering recommends approval of the grading plan.

GRADING PERMIT CONDITIONS:
The following 19 conditions apply to permit T08BU00035:
1) This grading plan and SWPPP are for the north parking area improvements only.
2) For inspection purposes, please fill out the enclosed "AZPDES - Posting Requirements" green sheet, and post at construction entrance of the site at beginning of construction activities and maintain this posted document throughout project construction.
3) A copy of the NOI, Stormwater Pollution Prevention Plan (SWPPP), Grading Plan and Grading Permit shall be kept at the site at all times, until final grading approval.
4) Provide completed NOI per new requirements prior to scheduling Pre-con or beginning work.
5) The operator signatures must be provided for the operators statement on the site copy of the SWPPP at or before commencement of construction.
6) Call for Pre-construction meeting, intermediate and final inspections. For a DSD Engineering Inspection, call IVR (740-6970), or contact DSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html
7) Temporary erosion/stormwater controls may be field adjusted with discussions with operators and engineer of record as necessary along disturbance limits for this project.
8) Designated concrete washout locations are required and shall not be located in or near the basin or water harvesting areas. Location of temporary material or vehicle staging / stockpile area shall be placed within grading limits and not located in any water harvesting or basin areas.
9) Any drain rock material that is placed along the base of the silt fence shall not obstruct or divert stormwater flow. If drain rock is not used with silt fence, then earthen material shall only be backfilled against silt fence at grade to allow maintenance of flow pattern.
10) There shall be no disturbance outside of the disturbance/grading limits, and no grading shall begin until all required SWPPP controls are installed.
11) Truncated domes are required for any access ramps per ADAAG.
12) Contact Permits and Codes (791-5100) for any questions regarding any right-of-way permit requirements.
13) Separate building permit applications are required for any walls.
14) Any revision to the Grading Plan may require a re-submittal of a revised grading plan for review. Contact DSD Engineering to discuss changes in grading design.
15) If grading construction is expected to last longer than the expiration date of the grading permit, contact DSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required.
16) Prior to final approval, as-builts are required with the letters of completion for overall project.
17) Prior to request for final inspection approval, any outstanding fees shall be paid.
18) The permitee shall notify the DSD when the grading operation is ready for final grading inspection. Final grading approval shall not be given until all work, including installation of all drainage improvements, including any scuppers, and their permanent protective devices, and all erosion control measures have been completed, and all conditions of permit are completed.
19) Prior to request for final grading inspection approval, all permanent erosion control improvements shall be installed and accepted by DSD including rock / established revegetation for all disturbed areas if not improved as per approved plan.

Grading Plans will be stamped approved after resubmittal for Zoning and Landscaping. Please call me for clarifications at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services

Final Status

Task End Date Reviewer's Name Type of Review Description
03/10/2008 CPIERCE1 OUT TO CUSTOMER Completed
03/10/2008 SHANAE POWELL REJECT SHELF Completed