Permit Review Detail
Review Status: Completed
Review Details: LUCAPPS - OVERLAY ZONE REV
Permit Number - T07SA00161
Review Name: LUCAPPS - OVERLAY ZONE REV
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/25/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: T07SA00161 El Dorado Country Club Estates Overlay Zone Review TRANSMITTAL DATE: September 20, 2007 DUE DATE: October 5, 2007 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Overlay Zone case number, T07SA00161, must be noted in the lower right corner of each sheet of the development plan, landscape, and NPPO plans. All required elements of the W.A.S.H. as shown on the approved Overlay Zone plan must be added to the development plan, along with date of approval and any conditions placed on that approval. The development plan may not be approved prior to Overlay Zone application approval. City Code Sec. 29-12 through 29-19 2. Zoning has no issues with the W.A.S.H Ordinance review and will approve the plan when all comments for the review have been addressed and DSD Engineering and Landscape sections have approved the plan. If you have any questions about this transmittal, please call Karol Aragonez, (520) 837-4960. KAA S:\zoning review\karol\planning\cdrc\overlay zone review\T07SA00161oz.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents. |
| 10/01/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | The Landscape Section has reviewed the application and requests the following additions and clarifications: 1. Revise the development plan and the Environmental Resource Report to include the same floodplain information. The limits differ. 2. Ownership of the Protected Riparian Area shall be provided in one or more of the methods set forth in DS 2-13.2.6 to insure continued preservation of the area. Refer to the standards and revise the plans and provide additional documentation as appropriate. A conservation easement or similar instrument is required. 3. Revise the Development Plan to identify and delineate the new Protected Riparian Area (preservation and mitigation areas).This area should at least cover the mitigation areas within the WASH study area and drainage easement. Revise the plans as necessary. TCC 23A-51.2 4. Correct the Total Mitigation calculations for Prosopis velutina on NPPP 3. It appears that 35 is the minimum mitgation requirement. |
| 11/06/2007 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | DATE: November 6, 2007 SUBJECT: The Lofts at Dorado Country Club TO: Patricia Gehlen, CDRC/Zoning Manager LOCATION: 3301 E Speedway, T14S R15E Sec 6, Ward 2 REVIEWER: Bianca Ramirez, CFM ACTIVITY: T07SA00161 (1st Review) RESUBMITTAL REQUIRED: W.A.S.H. (1st Review). The Drainage report and W.A.S.H. submittal has been reviewed by the Engineering Division. The Engineering Division has approved the submitted information for W.A.S.H. review only. See attached comments for information for forthcoming submittals. W.A.S.H Documentation: 1. The WASH study area and 10-year floodplain delineation's as described in the drainage report are accepted for WASH review purposes. 2. Additional comments may be forthcoming on development plan review once the WASH review process is completed. If you have any questions, I can be reached at 520.837.4928 or Bianca.Ramirez@tucsonaz.gov . Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax |
| 11/07/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 7, 2007 Michael Marks, AICP MJM Consulting Inc. 7002 E. 4th Street Tucson, Arizona 85710 Subject: T07SA00161 WASH Overlay for El Dorado Country Club (D07-0019) Dear Michael: Your submittal of September 7, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Overlay zone submittal package as detailed in the on line comments (Landscape, DSD). The public comment period will be opened during the next two weeks. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 885-5021 |