Permit Number: T07SA00150
Parcel: 13612001N

Address: Unknown

Review Status: Completed

Review Details: LUCAPPS - OVERLAY ZONE REV

Permit Number - T07SA00150
Review Name: LUCAPPS - OVERLAY ZONE REV
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2007 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: T07SA00150
Golf Links & Houghton
Overlay Zone

TRANSMITTAL DATE: September 11, 2007

DUE DATE: September 19, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Overlay Zone case number, T07SA00150 (no longer SCZ number), must be noted in the lower right corner of each sheet of the tentative plat, landscape, and NPPO plans and changed in general note 1 on DP4.0. All required elements of the SCZ as shown on the approved Overlay Zone plan must be added to the tentative plat/development plan, along with date of approval and any conditions placed on that approval. The tentative plat may not be approved prior to Overlay Zone application approval.
LUC 2.8.2

2. Please add to the end of general note 5 on sheet DP4.0 and general note 44 on sheet DP1.0 "in Land Use Code Sec. 3.7.3, Screening Requirements".

3. Please correct the spelling of the word "length" in general note 10 on sheet DP4.0.




If you have any questions about this transmittal, please call Karol Aragonez, (520) 837-4960.

KAA S:\zoning review\karol\planning\cdrc\developmentplan\T07SA00150oz.doc


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan/tentative plat.
09/14/2007 JOE LINVILLE LANDSCAPE REVIEW Denied The Landscape Section does not recommend approval at this time.

1) LUC 2.8.2.6.states that "Drainageways are to be maintained in their natural states where possible, and the discretionary authority (City Engineer) shall be exercised only under unusual circumstances."

Revise the plans to preserve the drainage in a natural state, except for the permitted improvements indicated on the Preliminary Development Plan. There do not appear to be any additional unusual circumstances and the rezoning condition restricts modification of the natural drainageway.
09/24/2007 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 09/24/2007

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Sorrento Square Retail Center
T07SA00150, T14S, R15E, SECTION 26
Ref. D07-0014

RECEIVED: Scenic Route Overlay Zone submittal on August 21, 2007

The subject submittal has been reviewed. We offer the following comments. Prepare a detailed response that explains the revisions that were made and references the exact location on the Development Plan where the revisions were made:

1. Clearly show the 30' natural buffer on the Development Plan exhibit.
2. The proposed improvements still show some encroachments into the 100-year floodplain, which does not comply with the requirements of the requirements of Rezoning Condition #15 and Development Standard 2-13.0. Clarify what appears to be ripraped areas within the floodplain of the "Xeroriparian Intermediate Habitat" Wash. (see Figure 4). This encroachment appears to be unnecessary and can be pulled out of the regulatory floodplain area. Address this issue and revise as necessary.
3. There are several drainage issues related to wash HEC RAS analysis that have not been addressed yet. Once the Drainage Report is approved, the Overlay Zone review can be better accomplished.


RESUBMITTAL REQUIRED: Revised Development Plan, Drainage Report and Scenic Route Overlay Submittal
09/25/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 25, 2007

Eric Fletcher
SBBL Architecture & Planning
1001 North Alvernon Way #105
Tucson, Arizona 85711

Subject: T07SA00150 Scenic Corridor Overlay Zone for SWC of Golf Links and Houghton (D07-0014)

Dear Eric:

Your submittal of August 21, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Overlay zone submittal package as detailed in the on line comments (Landscape, Zoning, Engineering, DSD).


The public comment period will be opened during the next two weeks.





Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager