| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/06/2007 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | 1. Within the 30' scenic route buffer area, indigenous plant material is to remain. If any disturbance occurs during construction or prior to permit application, the buffer area is to be revegetated with native plants indigenous to the site and the area reconstructed to look as natural as possible. DS 2-06.7.1.B. Per DS 2-06.4.1 the landscape plans must include a comprehensive list of native vegetation that exists on the site and in the immediate areas surrounding the site. Selection of plant material for use in the Scenic Corridor Zone buffer area will be from that comprehensive list. 2. All landscaping, including preservation and reestablishment of native vegetation, shall comply with Sec. 3.7.5.2, Scenic Routes. 3. The Native Plant Preservation Plan must clearly indicate the limits of grading per DS 2-15.3.4.A.1 4. One-hundred-and-fifty plants are proposed to be transplanted on site. A temporary nursery area is required to hold plants proposed for salvaging and transplanting. Indicate the temporary nursery area on the native plant preservation plan. DS 2-15.3.4.A.5 5. No grading can occur until thirty (30) days prior to construction. Construction plans must be in the review process for permits, or construction permits must have already been issued. Grading permits are to cover only those areas for which building permits are granted. LUC 2.8.2.13 6. Add the Overlay Zone case number (T07SA00091) to the lower right corner of each sheet of the tentative plat, landscape plan, and native plant preservation plan. LUC 2.8.2 |
| 11/26/2007 | HEATHER THRALL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Heather Thrall Senior Planner PROJECT: T07SA00091, Scenic Corridor Overlay Review Old Vail Plaza (Tentative Plat S07-156) TRANSMITTAL DATE: November 26, 2007 DUE DATE: November 14, 2007 COMMENTS: 1. Please note the Scenic Corridor Overlay Review has also been done in the review for the Tentative Plat, and thus comments from the tentative plat review are the same for the comments below for this separate Scenic Corridor Review. 2. Per LUC 2.8.2.3, the Scenic Corridor overlay applies to all real property within 400' of the FUTURE right of way line. Page 8 and 9 show the Scenic Corridor overlay measured from the CURRENT right of way line. Please revise the 400' mark, and please note that further comments on building height may be applicable if the buildings in this revised area are over 30' in height. 3. Provide building heights to allow staff to review the project for SCZ compliance with height requirements. Provide the heights at each lot and also listed on the Building Use Area Notes on sheet 1. Call out heights from grade to the highest portion of the building, clarify if roof flat or parapet and call out those heights - and/or call out the ridge and midpoint of the ridge - also from grade. A) I see in the SCZ submittal packet that a list of proposed building, paint and sign colors are included. Are these all the colors that will be provided? Note that all colors shall be of earth tone - and note that any changes to colors should be clarified on the resubmittal of the SCZ package as well. B) Provide notations for all view shed corridors with calculations - staff recommends this is provided as a separate sheet within the package of the development plan and the scenic corridor submittal. C) Contact Patricia Gehlen at DSD CDRC for requirements for SCZ submittal process D) Provide SCZ information on both the separate SCZ submittal and development plan E) Include in 30 foot buffer label the notation "30 foot undisturbed natural buffer to be preserved and maintained in it's natural state". F) PROVIDE THIS NOTE: Individual SCZ case not required for each lot, but site plans, elevations, and colors must be submitted for each lot for review of compliance to Scenic Corridor Zone case number T07SA00091 for height, colors, and setbacks. G) in general note 28 of the DP, please add the case number T07SA00091 Maximum height of structures will be 1/3 the distance of the structure from the future right-of-way of Houghton, not to exceed 30 feet for commercial development from design grade. H) PROVIDE THIS NOTE: No grading beyond that is necessary for siting of buildings, drives, private yards, and structural improvements. All viable vegetation with a caliper of 4 inches or greater and all saguaro cacti will be preserved or relocated on the site per the Native Plant and Preservation Ordinance. I) PROVIDE THIS NOTE: Trenching is permitted for the placement of utilities lines, if area is revegetated in accordance with Land Use Code Sec. 3.7.5.2.D J) PROVIDE THIS NOTE: All areas between the MS & R right-of-way line and the existing street right-of-way that are disturbed by development shall be revegetated with native vegetation. K) PROVIDE THIS NOTE: All disturbed areas on the site that are visible from Houghton Road and are not covered by permanent improvements shall be revegetated with native plants, plants from the Drought Tolerant Plant List, or a combination of both. L) PROVIDE THIS NOTE: Exposed cut and fill slopes shall be no greater than 1-foot rise or fall over a 3-foot length. 4. Depending upon responses provided, further review comments may be forthcoming. Should you have any questions about this review, or wish to meet with me at any time, please contact me at Heather.Thrall@tucsonaz.gov or at 837-4951. C:\planning\cdrc\tentativeplat\S07-156 Old Vail Plaza.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Scenic Corridor Overlay Zone submittal. If you have any questions about this transmittal, please call (520) 791-5608. C: overlays: T07SA00091 SCZ Old Vail Plaza.doc |
| 11/29/2007 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | Laith Alshami, Engineering and Floodplain Review, 11/21/2007, TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: Old Vail Plaza T07SA00091, T15S, R15E, SECTION 26 Ref. S07-156 RECEIVED: Tentative Plat, Landscape Plan for Scenic Route Overlay Zone Review on October 16, 2007 The subject submittal has been reviewed and it can not be approved at this time. Address the following comments before review can continue. Prepare a detailed response that explains the revisions that were made and references the exact location in the drainage report and on the Tentative Plat where the revisions were made: 1. Show the grading limits within the 30' natural buffer area on the Native Plant Preservation Plan as required DS 2-15.3.4.A.1. Demonstrate minimizing the disturbance to the extent required for access and any other required activities within the buffer area. 2. Provide the Overlay Zone case number (T07SA00091) to the lower right corner of each sheet of the tentative plat, landscape plan, and native plant preservation plan. 3. The Tentative Plat has not been approved yet. The Overlay submittal will be approved after the Tentative Plat approval. RESUBMITTAL REQUIRED: Revised Tentative Plat, Native Plant Preservation Plan and Drainage Report |
| 12/03/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES December 3, 2007 Gregory D. Santoro DOWL Engineers 166 West Alameda Tucson, Arizona 85701 Subject: T07SA00091 Scenic Corridor Overlay for Old Vail Plaza (S07-156) Dear Gregory: Your submittal of October 16, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 4 Copies Revised Overlay zone submittal package as detailed in the on line comments (Zoning, Engineering, Landscape, DSD). The public comment period will be opened during the next two weeks. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 624-0384 |