Permit Number: T07SA00036
Parcel: 11803324A

Address:
2302 W HELTON LN

Review Status: Completed

Review Details: RESUBMITTAL - OVERLAY ZONE REVIEW

Permit Number - T07SA00036
Review Name: RESUBMITTAL - OVERLAY ZONE REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/16/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approved DATE: August 16, 2007
SUBJECT: 2302 W HELTON LN Overlay Resubmittal Review
LOCATION: T14S, R13E, Section 21, Ward 1
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: T07SA00036

Summary: Grading occurred at this site prior to obtaining a grading or modular home permits. This site falls with in the Hillside Development Zone Overlay area. A revised grading plan resubmittal and HDZ review was reviewed by Engineering Division at a meeting on 1AUG07 to review whether all comments had been addressed and to check for compliance with grading standards and HDZ Overlay Land Use Codes. Engineering Division recommends approval of the overlay and grading plan. See grading permit T07BU00237 for conditions of permit.

I can be reached at 837-4934 if you have questions.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department
08/17/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
09/06/2007 HEATHER THRALL ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall, Senior Planner

PROJECT: T07SA00036, 2302 W. Helton, Manufactured Home
Special Overlay Zone Application, Hillside Development Zone Review

TRANSMITTAL DATE: September 6, 2007

DUE DATE: September 6, 2007

COMMENTS: CONDITIONAL APPROVAL

As the applicant is new to this process and is requesting specific instruction to finish, I have outlined the items below that need to be done to finalize this project.

1. Increase text size on the site map to a minimum of 12 point - elevation & utility notes.

2. A permit application was issued for the proposed manufactured home T07MH00014. That separate site plan was not included in the overlay resubmittal, thus it is assumed the drawing submitted in the overlay review shall serve as the site plan for both applications. Add the following to the drawing:
A) declare the unit is a manufactured home
B) show setbacks to all property lines (I scaled drawing, large setbacks meet LUC),
C) dimension building footprint
D) declare the MH-1 zoning of the site and MH-1 zoning of adjacent lots
E) list a separate heading to call out the lot coverage calculation listed in the area table.

3. Please resubmit the overlay plan with this data to the CDRC office, then go to the permit counter and have a new work flow started for the building permit number T07MH00014. Email me when this is done. I will look at the plan as quickly as possible and advise the CDRC manager of my findings. TO FURTHER CLARIFY, THE SAME SITE DRAWING IS TO BE USED FOR BOTH APPLICATIONS.

3. Please note, depending upon responses provided, further review comments may be forthcoming. Should you have any questions on this review, please contact me at Heather.Thrall@tucsonaz.gov or at 520-837-4951.

C:\planning\cdrc\developmentplan\T07SA00036 2302 w helton 2.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: all drawings.
09/13/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 13, 2007

Sheila Millette
ABC Mobile Movers
4275 North Plum
Tucson, Arizona 85705

Subject: T07SA00036 Hillside Development Overlay Zone for Single Family Mobile Home at 2302 West Helton Lane (T07MH00014)

Dear Sheila:

The above referenced overlay zone application has been APPROVED CONDITIONALLY by the Community Design Review Committee. Please make the requested revisions to the site plan and resubmit for review per the on-line comments.


PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE OVERLAY CASE NUMBER, DATE OF APPROVAL, TYPE OF OVERLAY, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.




Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager