Plan Number: T07PI00046
Parcel: Unknown

Review Status: Completed

Review Details: PIA SUBMITTAL

Plan Number - T07PI00046
Review Name: PIA SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/09/2008 RICHARD LEIGH DOT ENGINEERING REVIEW Denied January 9, 2008

SUBJECT: Venado Vista, Offsite Improvements PIA Plan T07PI0046

PROJECT REVIEWER: Richard Leigh, Permits and Codes Section

RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal.

1. Include COT Development Services activity number "T07PI00046" on cover sheet.

2. Include the plan number "I-2008-001" in the title block of each sheet.

3. Include the street names "Melpomene Way" in title of plan.

4. Sheet 4, detail 8: The lateral transition of the sidewalk shall not exceed 3 longitudinal to 1 lateral.

Refer to redline plans for additional comments and comment details.

If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov.
01/17/2008 GARY WITTWER DOT LANDSCAPE REVIEW Denied The aerial photo shows lots of native vegetation in the area. Please address the Native Plant Preservation Ordinance.
01/18/2008 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Denied We have reviewed this plan and have the following comment:

1. Will there be any landscaping installed with this project? If so, please submit the landscape plan to Paul Rosenboom at 4004 S. Park Ave, Bld #2 for review.
01/30/2008 SMONTIE1 PIA COORDINATOR CUSTOMER CALLED Completed
01/30/2008 JOSE ORTIZ DOT TRAFFIC REVIEW Denied January 29, 2008
ACTIVITY NUMBER: T07PI00046
PROJECT NAME: Venado Vista Estates
PROJECT ADDRESS: 1470 S Melpomene Wy
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal. Include a response letter with the next submittal that states how all comments have been addressed. The following items must be revised or added to the plan.

1. See redlines on the submitted drawings and address the additional redline comments. During the next submittal please re-submit the roll of redlines for back checking purposes.

2. Stop bars and cross walks are not warranted at this location so remove from plans.

3. The dirt driveway on the east leg of the Melpomene/Raod A intersection needs to be adjusted to the north to align with Road A. This is in an effort to avoid left turning conflicts.

4. Install a W14-2a (No Outlet) plaque beneath the street name signs along.

5. Place the PIA and CDRC Case number on the cover sheet.

6. Add the following Signing General Notes 5(a) & 5(b) per PCDOT & TDOT Signing Manual (2002) (Chapter 1, Sheet 12) to the Plans.

7. Add the following Pavement Marking/Striping General Notes to the Plans:

'ALL STREET STRIPING & SIGNAGE TO BE COORDINATED WITH C.O.T. TRAFFIC ENGINEERING CALL 791-4259 A MINIMUM OF 48 HOURS PRIOR TO THE INSTALLATION OR REMOVAL OF ANY SIGNAGE OR STRIPING. ALL REQUIRED STRIPING AND SIGNAGE WILL BE INSTALLED AT THE CONTRACTOR'S EXPENSE. NEW STRIPING TO BE THERMOPLASTIC MATERIAL. USE 2" SQUARE-TUBE POST AND SQUARE TUBE POST FOUNDATIONS FOR SIGNING. BARRICADE PLAN MUST BE SUBMITTED TO THE CITY OF TUCSON TRAFFIC ENGINEERING FOR APPROVAL 48 HOURS IN ADVANCE OF ANY WORK IN PUBLIC RIGHT OF WAY.'

'ALL NON-SIGNALIZED INTERSECTION STREET NAMES MUST HAVE E-W BLOCK NUMBER ADDRESSES FOR E-W ROADWAYS AND N-S BLOCK NUMBER ADDRESSES FOR N-S ROADWAYS.'

'THE CITY SHALL NOT BE LIABLE FOR ANY ERRORS AND/OR OMISSIONS ON THESE PLANS. ITEMS NOT MEETING CITY STANDARDS SHALL BE REPAIRED/REPLACED BY THE DEVELOPER/CONTRACTOR AND AT NO COST TO THE CITY.'

If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov
01/30/2008 SMONTIE1 PIA COORDINATOR OUT TO CUSTOMER Completed
12/28/2007 SMONTIE1 UTILITY CLEARANCES COT STREETS DIVISION Denied Please submit utility clearance letters for:
Transportation streets, TEP, and Cox Communications

Thank You
12/28/2007 SMONTIE1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed Please submit utility clearance letters for:
Transportation streets, TEP, and Cox Communications

Thank You
12/28/2007 SMONTIE1 UTILITY CLEARANCES PC WASTEWATER MGMT Completed Please submit utility clearance letters for:
Transportation streets, TEP, and Cox Communications

Thank You
12/28/2007 SMONTIE1 UTILITY CLEARANCES QUEST COMMUNICATION Completed Please submit utility clearance letters for:
Transportation streets, TEP, and Cox Communications

Thank You
12/28/2007 SMONTIE1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied Please submit utility clearance letters for:
Transportation streets, TEP, and Cox Communications

Thank You
12/28/2007 SMONTIE1 UTILITY CLEARANCES COX COMMUNICATION Denied Please submit utility clearance letters for:
Transportation streets, TEP, and Cox Communications

Thank You
12/28/2007 SMONTIE1 UTILITY CLEARANCES SOUTHWEST GAS CORP Completed Please submit utility clearance letters for:
Transportation streets, TEP, and Cox Communications

Thank You
12/28/2007 SMONTIE1 UTILITY CLEARANCES EL PASO NATURAL GAS Completed Please submit utility clearance letters for:
Transportation streets, TEP, and Cox Communications

Thank You
12/28/2007 SMONTIE1 UTILITY CLEARANCES KINDER MORGAN ENERGY Completed Please submit utility clearance letters for:
Transportation streets, TEP, and Cox Communications

Thank You