Plan Review Detail
Review Status: Completed
Review Details: PIA RESUBMITTAL
Plan Number - T07PI00026
Review Name: PIA RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/14/2008 | THAD HARVISON | DOT ENGINEERING | REVIEW | Denied | 1. As previously stated box culverts are designed to convey flows and vertical loads not lateral loads at the edges of the walls. Highly recommend extending the box culvert to accommodate the pedestrian pathway. Additionally, provide a structural analysis, stamped by a structural engineer, for the proposed pedestrian bridge attached to the box culvert. The analysis must demonstrate the box culvert has the capacity to carry the additional loads. 2. Show the Detectable Warning Strip per COT/PC Standard Detail 207 on Detail 4 (Concrete Curb Access Ramp), page 32 of 99. |
| 01/15/2008 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
| 01/16/2008 | SMONTIE1 | PC-PARK & REC | PIMA COUNTY PARKS AND RECREATION | Approved | |
| 01/16/2008 | SMONTIE1 | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 01/16/2008 | SMONTIE1 | PARK AND RECREATION | REVIEW | Approved | |
| 01/16/2008 | SMONTIE1 | PIA COORDINATOR | OUT TO CUSTOMER | Completed |