Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: T07PI00024
Parcel: Unknown

Address:
9047 S RITA RD

Review Status: Completed

Review Details: PIA RESUBMITTAL

Plan Number - T07PI00024
Review Name: PIA RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/01/2007 SMONTIE1 UTILITY CLEARANCES COT STREETS DIVISION Approved
11/01/2007 SMONTIE1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Approved
11/01/2007 SMONTIE1 UTILITY CLEARANCES PC WASTEWATER MGMT Approved
11/01/2007 SMONTIE1 UTILITY CLEARANCES QUEST COMMUNICATION Approved
11/01/2007 SMONTIE1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Approved
11/01/2007 SMONTIE1 UTILITY CLEARANCES COX COMMUNICATION Approved
11/01/2007 SMONTIE1 UTILITY CLEARANCES SOUTHWEST GAS CORP Approved
11/01/2007 SMONTIE1 UTILITY CLEARANCES EL PASO NATURAL GAS Approved
11/01/2007 SMONTIE1 UTILITY CLEARANCES KINDER MORGAN ENERGY Approved
11/07/2007 GARY WITTWER DOT LANDSCAPE REVIEW Approved
11/20/2007 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Denied We have reviewed this plan and have the following comments:
1. Sheet 3 &4 - RCP's - The city will need a way to get men and equipment into the basins to maintain the pipes. (ramp of some kind)
2. Sheet 3 & 4 - Basins - Who will be responcible for the maintenance of the basins?
11/28/2007 RICHARD LEIGH DOT ENGINEERING REVIEW Denied November 27, 2007

SUBJECT: Target Fulfillment center West , PIA Plan T07PI0024

PROJECT REVIEWER: Richard Leigh, Permits and Codes Section

RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal.

1. Indicate the limits for any for any proposed barricade railing.

2. The roadway names listed on plan set do not correspond with approved tentative plat. Verify and correct.

3. Provide a curb access ramp opposite of the access ramp at the northeast or northwest corner of Rita Tech Place and Target Way.

4. Provide vertical curves for roadway grades, which have an algebraic difference greater than 1%. The minimum desired vertical curve length is 100 feet.

5. The approved drainage report indicated the placement of (3) 36" RCP storm drains at Sta. 14+95.45 Target Way while only two are proposed in the paving plans. Clarify the discrepancy.

6. Who will be responsible for the maintenance for the basin equalizer pipes across Rita Park Place and Target Way? If the development will be responsible for the pipes, indicate it on plan view.

If you have any questions, I can be reached at 837-6647 or at Richard.Leigh@tucsoz.gov
11/30/2007 SMONTIE1 PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSADOR Completed
11/30/2007 JOSE ORTIZ DOT TRAFFIC REVIEW Approv-Cond Address red-lines provided on the submitted plans prior to the submittal of the mylars.
11/30/2007 SMONTIE1 PIA COORDINATOR OUT TO CUSTOMER Completed