| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/20/2007 | ASHOFFS1 | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf |
| 07/20/2007 | ASHOFFS1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf |
| 07/20/2007 | ASHOFFS1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf |
| 07/20/2007 | ASHOFFS1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf |
| 07/20/2007 | ASHOFFS1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf |
| 07/20/2007 | ASHOFFS1 | UTILITY CLEARANCES | COX COMMUNICATION | Denied | Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf |
| 07/20/2007 | ASHOFFS1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf |
| 07/20/2007 | ASHOFFS1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf |
| 07/20/2007 | ASHOFFS1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf |
| 08/07/2007 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | 1. Please address the Native Plant Preservation Ordinance. 2. Please submit all proposed landscape and irrigation plans for the ROW. |
| 08/09/2007 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | We have reviewed this plan and have the following comments: 1. Sheet 2 - Is there access for maintenance crews to be able to clean the inlet and the outlet of the proposed box culvert? 2. Note 5 - This note references a lighting plan for this project. Please submit this plan to Ernie Encinas at 4004 S. Park Avenue, Bld #2 for review. 3. Will there be any landscaping with this project? If so, please submit the irrigation and landscaping plan to Paul Rosenboom at 4004 S. Park Ave, Bld#2 for review. 4. All work in the right of way needs to be coordinated with Paul Rosenboom at 791-3154 ext 234. |
| 08/10/2007 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | August 10, 2007 SUBJECT: Target Fulfillment center West , PIA Plan T07PI0024 PROJECT REVIEWER: Richard Leigh, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. Include the recordation information of the recording instrument for the project on cover sheet. 2. Include the plan number "I-2007-034" in title blocks. 3. Include the Development Services activity number "T07PI00024" on cover sheet. 4. Submit the hydraulic analysis for sizing the proposed drainage structures (Pipe culverts, box culverts, sidewalk scuppers, roadway capacities and scour protection) for review. All the proposed drainage structures have not been addressed in the submitted drainage report. 5. Submit a copy of a geotechnical engineering report supporting the proposed pavement structural section with next submittal. 6. Provide a dimensioned detail of each type of proposed curb access ramp in plan set. Additionally, indicate the use of truncated domes as the detectable warning device. 7. Provide complete details for the proposed drainage structures include inverts, slopes, skew, pipe class, dimensions and Etc. 8. Has the lighting plan for the proposed Luminaries been reviewed and approved by the City of Tucson, Street and Traffic Maintenance Electric Shop? Reference lighting plan number in paving plan set. 9. Label common areas adjacent to the proposed roadways. 10. Sheet 2: Provide complete left and right profile views for Rita Tech Place. 11. Sheet 3: Indicate the grades of the left and right gutter in the profile view. 12. Sheet 5 Detail E and F: Provide headwalls for the proposed pipe crossings. 13. Provide a dimensioned detail of the proposed sidewalk scupper with appropriate cross sections. 14. Indicate the placement of barricade railing per PC/COT Standard Detail 105 at the pipe and box culvert crossings. 15. Refer to redline plans for additional comments and comment details. 16. If you have any questions, I can be reached at 837-6647 or at Richard.Leigh@tucsoz.gov |
| 08/20/2007 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | Waiting on recomeended lane geometry configuration from Consultant. No comments generated at this time. Additional comments will be generated with final design. |
| 08/21/2007 | LHENDRI1 | PIA COORDINATOR | CUSTOMER CALLED | Completed | |
| 08/21/2007 | LHENDRI1 | PIA COORDINATOR | OUT TO CUSTOMER | Completed |