Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: T07PI00024
Parcel: Unknown

Address:
9047 S RITA RD

Review Status: Completed

Review Details: PIA SUBMITTAL

Plan Number - T07PI00024
Review Name: PIA SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/20/2007 ASHOFFS1 UTILITY CLEARANCES COT STREETS DIVISION Denied Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf
07/20/2007 ASHOFFS1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf
07/20/2007 ASHOFFS1 UTILITY CLEARANCES PC WASTEWATER MGMT Denied Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf
07/20/2007 ASHOFFS1 UTILITY CLEARANCES QUEST COMMUNICATION Denied Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf
07/20/2007 ASHOFFS1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf
07/20/2007 ASHOFFS1 UTILITY CLEARANCES COX COMMUNICATION Denied Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf
07/20/2007 ASHOFFS1 UTILITY CLEARANCES SOUTHWEST GAS CORP Denied Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf
07/20/2007 ASHOFFS1 UTILITY CLEARANCES EL PASO NATURAL GAS Denied Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf
07/20/2007 ASHOFFS1 UTILITY CLEARANCES KINDER MORGAN ENERGY Denied Please submit Utility Clearance Letters. You can find the form at http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/UTLAWAREMEM__revised_062007_.pdf
08/07/2007 GARY WITTWER DOT LANDSCAPE REVIEW Denied 1. Please address the Native Plant Preservation Ordinance.
2. Please submit all proposed landscape and irrigation plans for the ROW.
08/09/2007 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Denied We have reviewed this plan and have the following comments:

1. Sheet 2 - Is there access for maintenance crews to be able to clean the inlet and the outlet of the proposed box culvert?
2. Note 5 - This note references a lighting plan for this project. Please submit this plan to Ernie Encinas at 4004 S. Park Avenue, Bld #2 for review.
3. Will there be any landscaping with this project? If so, please submit the irrigation and landscaping plan to Paul Rosenboom at 4004 S. Park Ave, Bld#2 for review.
4. All work in the right of way needs to be coordinated with Paul Rosenboom at 791-3154 ext 234.
08/10/2007 RICHARD LEIGH DOT ENGINEERING REVIEW Denied August 10, 2007

SUBJECT: Target Fulfillment center West , PIA Plan T07PI0024

PROJECT REVIEWER: Richard Leigh, Permits and Codes Section

RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal.

1. Include the recordation information of the recording instrument for the project on cover sheet.

2. Include the plan number "I-2007-034" in title blocks.

3. Include the Development Services activity number "T07PI00024" on cover sheet.

4. Submit the hydraulic analysis for sizing the proposed drainage structures (Pipe culverts, box culverts, sidewalk scuppers, roadway capacities and scour protection) for review. All the proposed drainage structures have not been addressed in the submitted drainage report.

5. Submit a copy of a geotechnical engineering report supporting the proposed pavement structural section with next submittal.

6. Provide a dimensioned detail of each type of proposed curb access ramp in plan set. Additionally, indicate the use of truncated domes as the detectable warning device.

7. Provide complete details for the proposed drainage structures include inverts, slopes, skew, pipe class, dimensions and Etc.

8. Has the lighting plan for the proposed Luminaries been reviewed and approved by the City of Tucson, Street and Traffic Maintenance Electric Shop? Reference lighting plan number in paving plan set.

9. Label common areas adjacent to the proposed roadways.

10. Sheet 2: Provide complete left and right profile views for Rita Tech Place.

11. Sheet 3: Indicate the grades of the left and right gutter in the profile view.

12. Sheet 5 Detail E and F: Provide headwalls for the proposed pipe crossings.

13. Provide a dimensioned detail of the proposed sidewalk scupper with appropriate cross sections.

14. Indicate the placement of barricade railing per PC/COT Standard Detail 105 at the pipe and box culvert crossings.

15. Refer to redline plans for additional comments and comment details.

16. If you have any questions, I can be reached at 837-6647 or at Richard.Leigh@tucsoz.gov
08/20/2007 JOSE ORTIZ DOT TRAFFIC REVIEW Denied Waiting on recomeended lane geometry configuration from Consultant. No comments generated at this time. Additional comments will be generated with final design.
08/21/2007 LHENDRI1 PIA COORDINATOR CUSTOMER CALLED Completed
08/21/2007 LHENDRI1 PIA COORDINATOR OUT TO CUSTOMER Completed