Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T07PI00019
Parcel: Unknown

Review Status: Completed

Review Details: PIA RESUBMITTAL

Plan Number - T07PI00019
Review Name: PIA RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2008 GARY WITTWER DOT LANDSCAPE REVIEW Denied Thanks for the NPPO plan. I still have a problem with the irrigation plan. It indicates that you intend to install lateral lines under public roadways. You can do this with an easement, but it needs to be recorded. If you want to go this route call 791-5100 and I can give you all of the requirements, or add another meter.
01/03/2008 JOSE ORTIZ DOT TRAFFIC REVIEW Denied January 3, 2008
ACTIVITY NUMBER: T07PI00019
PROJECT NAME: I-10 and Kolb Road
PROJECT ADDRESS: 6751 E Hermans Road
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal.

The following items must be revised or added to the plan.

1. Include a response letter with the next submittal that states how all comments have been addressed.

2. See redlines on the submitted drawings for preferred sign locations. During the next submittal please re-submit the roll of redlines for back checking purposes.



If you have any questions, I can be reached at 837-6730 or Jose.Ortiz@tucsonaz.gov
01/08/2008 Blanca Espino DOT ENGINEERING REVIEW Denied PIA Plan
1. Please include a detail letter of explanation with the next submittal indicating where and how revisions were made. Single word responses are unacceptable. Include plans/redlines from previous plan submittal.

2. Reminder, Maps and Plats, Book and Page should be noted on cover sheet of subdivision street improvement plans. Plat must be recorded before submittal of mylars for final review and approval.

3. Reminder, Indicate All Easements, dedications, right-of-way should be depicted in plan view and labeled with recordation information (docket/page or plat book/page). Apply this information where there is an Easement of any kind or where it reads "Dedicated by Final Plat". Correct and revise. See redlines for additional corrections.

4. Sheet 2, General Notes - add this note: Pipe bedding shall conform to PC/COT Standard Detail 108.

5. Sheet 3, Curb Knuckle inside radius is to be 25' and parallel with the Property line. Sidewalk area is to have the same continuous curvature. Correct. See D.S. 3-01.10.Figure 22

6. Sheet 3, Indicate the handicap ramp opening along left curb line in Profile. Indicate % Slope.

7. Sheets 3 thru 9; Label the Proposed Top of Curb, Proposed Gutter Line, Proposed Grade @ CL of Road, and Grades for Left & Right profile. See redlines for corrections.

8. Indicate the Pipe Class for each proposed RCP.

9. Indicate all curb line drainage structures on Profile views.

10. Callout Construction Note #8 for all wedge curb to vertical curb and or catch basins.

11. Sheet 4, Indicate Private, Proposed or Common Area for 20' Drainage Easement By Final Plat, Book ___ & Page ___. This information must coincide with the approved Tentative Plat.

12. Construction Notes 9, 10 & 11 do not reflect the construction information as noted in the PC/COT Standard Details for Public Improvements, 2003 Edition. If these details are to be modified, indicate the word MODIFIED

13. Sheet 5, Provide Post Barricades (Removable) to restrict vehicle traffic for the 15' Maintenance Access area. Indicate a driveway apron per PC/COT 206.

14. Sheet 5, Cul-de-sac area indicates a basin with 4 to 1 slopes adjacent to sidewalk. This conflicts with the cross section & detail 12 of sheet 10. Correct.

15. Sheets 5 & 7; Callout the Transition from Wedge curb to Sidewalk scupper. Indicate a dimensioned detail.

16. Sheet 5 & 7; Depict proposed Barricade railing along channel and indicate Limits (Stationing).

17. Sheet 6, Call out drainage structure at Station 16+00 and indicate on Left profile.

18. Sheet 7, Provide Headwalls & Barricade Railing for the one 24" RCP in the roadways of Paradise Cove Drive & Mermaid Cove Drive at Hermans Road.

19. Sheet 7, Demonstrate that Scour Protection may or may not be warranted on Hermans Road @ Station 17+40.15.

20. Sheet 8 is duplicated. Remove extra sheet.

21. Sheet 10, Detail 9; Make the dimension text legible. Indicate the Centerline of the Flow line.

22. Sheet 10, Details 11; label each curb access ramp as noted per the Redlines.

23. Sheet 11, Detail 1; Indicate Book & Page info. Indicate a Thickened Edge detail. The 2' hinge point must be on the private side from the right of way.

24. Sheet 11, Detail 2; Indicate the AC/ABC Thickness per the Geotechnical Report. An 8-foot wide area is required along the edge of pavement. The Key-In is to be built accordingly to Figure 8.1 of the Standards Manual for Drainage Design and Floodplain Management in Tucson. Indicate dimensions. Correct and revise.

25. Sheet 11, Details 4 & 5; Provide Structural Details for the Junction Structures. Must be sealed by a Structural Engineer.

26. Indicate a dimensioned detail for "Thickened Edge" and "Saw-cut, Trim, Tack & Join"

27. See redlines for additional corrections.


Once changes, modifications, and or corrections are made to the PIA plan resubmitted and reviewed, further comment may result. If you have any questions, I can be reached at 837-6634 or Blanca.Espino@tucsonaz.gov
01/09/2008 SMONTIE1 PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSADOR Completed
01/09/2008 SMONTIE1 PIA COORDINATOR OUT TO CUSTOMER Completed
12/03/2007 SMONTIE1 UTILITY CLEARANCES COT STREETS DIVISION Completed
12/03/2007 SMONTIE1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
12/03/2007 SMONTIE1 UTILITY CLEARANCES PC WASTEWATER MGMT Completed
12/03/2007 SMONTIE1 UTILITY CLEARANCES QUEST COMMUNICATION Completed
12/03/2007 SMONTIE1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Completed
12/03/2007 SMONTIE1 UTILITY CLEARANCES COX COMMUNICATION Completed
12/03/2007 SMONTIE1 UTILITY CLEARANCES SOUTHWEST GAS CORP Completed
12/03/2007 SMONTIE1 UTILITY CLEARANCES EL PASO NATURAL GAS Completed
12/03/2007 SMONTIE1 UTILITY CLEARANCES KINDER MORGAN ENERGY Completed
12/20/2007 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Approved