Permit Number: T07OT02408
Parcel: 12915006G

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T07OT02408
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/29/2008 MARTIN BROWN FIRE REVIEW Approved
04/29/2008 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Parking spaces may be designed so that the front of a vehicle overhangs into planter areas that are within a vehicular use area as long as the maximum amount of overhang is the same measurement as the parking space wheel stop location, as permitted in DS 3-05.2.3.C.2 See 2-06.8.0 Figure 5 for details http://www.ci.tucson.az.us/dsd/Codes___Ordinances/DevStdTOC2.pdf
Verify that planters within vehicle use meet criteria or redesign as necessary.

2. Submit proposed NPP plan.
04/30/2008 ANDREW CONNOR NPPO REVIEW Denied Submit proposed NPP plan.
04/30/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
05/14/2008 HEATHER THRALL ZONING REVIEW Denied TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: EXPIRED T06OT02036 - NEW NUMBER T07OT02408
899 E. Silverlake, UPS facility, new parking lot, greater than 25% expansion
Site plan, full code compliance
3rd review (2nd review of GLHN project submittal)

TRANSMITTAL DATE: May 15, 2008

COMMENTS: Please contact me at Heather.Thrall@tucsonaz.gov for an over the counter appointment to review the following minor changes, THANK YOU.

1. Planning Administration agrees this use is a Transportation Service, Land Carrier.

2. Per DS 2-02.2.1.8, with regards to parking/vehicular use areas:
A) On detail Q-7, put wheel stop to be COMPLETELY IN top 2'6"of parking space.

3. Per DS 2-02.2.1.11, re: PAALs
A) exit PAAL must be setback on both the north and the south sides, at least 2' away from fencing, per DS 3-05.2.2.B.3 ( just dimension, I scaled and it appears fine.)

4. Per DS 2-02.2.2.A.2, indicate actual floor area ratio - include all buildings - in decimal format (i.e. 55,462/461,736 = .12 FAR)

5. Please provide note at gate to north east of semi parking -" emergency access only".

6. Please provide wheel stops in vehicle spaces abutting building rather than bollards to allow vehicle overhang.

7. Thank you for providing the concrete walk along the handicapped parking leading to the guarded entry to the facility. Per DS 2-08.5.1C & 2-08.4.1.C, however, the sidewalk needs to continue a little farther east - between all parking spaces and adjacent building.

8. Please contact me at Heather.Thrall@tucsonaz.gov or at 791-4541x1156 to set up a counter appointment to review the above minor changes.



HCT C:\planning\site\DSD\T06OT02036 899 e silverlake ups 3rd.doc

THE FOLLOWING IS REQUIRED: Revised site plan
05/27/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
06/12/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: June 12, 2008
SUBJECT: New Parking Lot - Site Plan
TO: Donna Mertes
LOCATION: 899 E Silverlake, T14S, R14E, Section 19, Ward 5
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T07OT02408 (Second Review)


RESUBMITTAL REQUIRED: Site Plan

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the Site Plan.
2. With next submittal provide initial redlines generated from engineering comments from 10/10/06 for reference of previous comments.
3. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. Development Services has modified review procedures for handicap access. Please see any comments posted by Ron Brown.
4. Complied
5. Complied
6. Complied
7. D.S. 2-02.2.1.10: Show all existing and future site visibility triangles (SVT) on plan view for all (proposed and existing) PAAL access points. Revise the SVTs shown on the corner of Silverlake to read and measure 265'. Add SVT along Euclid Avenue for the corner of Silverlake Road and Euclid Avenue. Add SVT along Revise the SVTs for Park Avenue to reflect the dimensions for an Arterial Street. Verify that both existing and future SVTs depicted on site plan. If there is a stop sign from Euclid Avenue onto or across Silverlake Road provide SVT. Verify that all intersections have the appropriate SVT(s).
8. Complied
9. Complied
10. Complied
11. D.S. 2-02.2.1.14: Dimension the required maneuverability area for all loading zones that are indicated on the site plan. Refer to AASHTO for the national standards for turning radii.
12. Complied
13. Complied
14. DS Sec 2-02.2.1.A.19: Label existing and future right-of-ways for all streets indicated on site plan along with curb(s) and sidewalk locations (existing curb and sidewalk if maximum right of way taken). Label Euclid as a local street.
15. DS Sec 2-02.2.1.A.20: Verify dimensions for right of way for Euclid Avenue.
16. Complied
17. DS Sec.2-02.2.1.A.12: Indicate on the site plan and in details that all handicap access ramps at crosswalks and at the transition of a pedestrian circulation area to a vehicular use area have required detectable warning devices (truncated domes). See detail Q on sheet S7. Truncated domes only need to be located in the areas where no wheel stops are located.
18. Label the dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
19. Complied
20. D.S. 2-02.2.1.32: Provide detail for trash enclosure and identify on site plan.
21. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
22. Complied
23. DS Sec. 2-02.2.1.C: Add note to site plan - "Depress all landscaped areas 6" maximum for water harvesting".
24. Detail Q indicates striping for handicap areas. Indicate access ramps and truncated domes for detail and indicate on site plan accordingly. See detail Q on sheet S7. Truncated domes only need to be located in the areas where no wheel stops are located.
25. Clarify in legend - existing and proposed elevations.
26. Provide a cross section that clarifies existing and proposed loading zones.
27. Clarify what material is being used to support loading zones - what is the loading dock material constructed of?
28. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
29. Explain use/purpose of 14' paved area on sheet S4. It appears that it may need curb returns to exit onto Park Avenue.
30. Provide the area of disturbance which will be required for grading submittal.
31. Additional comments may be forthcoming.

DRAINAGE REPORT:
32. Complied
33. Complied
34. Complied
35. Clarify in report whether two (2) watersheds upstream of the proposed north basin conveys all the flow through the basin.
36. On sheet S4 the Q100 = 23 cfs, please check the flow along Park Avenue. City of Tucson data indicates higher flow(s). If the flow along Park Avenue is jurisdicational flow, any 100-year floodplain lines must be shown on your drainage exhibits and site plan.
37. Please provide spot elevations for the proposed 14' paved area to show how any flood condition flows are prevented from entering the site, as this project is a proposed cut condition.
38. Interceptor channel for north basin does not appear to be included in report. Provide updated watershed map exibit sincet the interceptor channel crosses watersheds.
39. Provide erosion protection for proposed basin side slopes (required for all unattenuated flow conditions regarless of slope grade).
40. Additional

GEOTECHNICAL REPORT:
41. DS Sec 10-01.III.3.5.1.3.a, 10-02.14.2.6: Provide a Geotechnical Report Evaluation that addresses the following:
a) Complied
b) Complied
c) Complied
d) Provide percolation rates for retention basing for 5-year threshold.

STORMWATER POLLUTION PREVENTION PLAN:
42. Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans (SWPPP) and text addressing stormwater controls for all areas affected by construction activities related to this development will be required with the re-submittal. For further information, visit www.adeq.state.az.us/environ/water/permits/stormwater.html. A SWPPP submittal will be required along with the grading permit. Every Construction General Permit required a separate SWPPP.
43. Grading plan will require full SWPPP - see ADEQ checklist to ensure that all items have been includedd in report.

Provide a revised site plan, drainage report, geotechnical engineering report and SWPPP that address the comments provided above. Include a comprehensive response letter addressing in detail responses to all the above comments.

Further comments may be forthcoming upon resubmittal of the site plan, drainage report, geotechnical report, and SWPPP reviews.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Regards,

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax

Final Status

Task End Date Reviewer's Name Type of Review Description
07/01/2008 CINDY AGUILAR OUT TO CUSTOMER Completed
07/01/2008 SUE REEVES REJECT SHELF Completed