Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: September 12, 2007
ACTIVITY NUMBER: T07OT01815
PROJECT NAME: Lecocq Duplex
PROJECT ADDRESS: 2645 North Edith Blvd.
PROJECT REVIEWER: Patricia Gilbert

FLOODPLAIN USE PERMIT IS DENIED

RESUBMITTAL REQUIRED: SITE PLAN, SITE PLAN APPLICATION, FLOODPLAIN USE PERMIT APPLICATION

1. Add a general note to the plan that the entire property lies within a City of Tucson Regulatory flood hazard area. DS 2-02.2.1.A.15.

2. In a general note provide the water surface elevation and include the datum. The water surface elevation is 2419.6' and the datum used for this elevation is NAVD 1988. DS 2-02.2.1.A.15.

3. The required finish floor elevation is 2420.6'. Add a note to the plan providing the required FFE and the datum (NAVD 1988).

4. Provide a general note on the site plan that this development contains a requirement that the applicant, or the applicant's authorized representative, complete an Elevation Certificate and is returned to the Development Services Department (DSD) Engineering Division prior to approval of the pre-slab inspection and the final inspection. Both of the original elevation certificates must be returned to the DSD Engineering Division.

5. This project will require a grading plan review and permit. It is recommended to submit a grading plan and the (green) grading application with the next submittal.

6. It appears the note regarding the manhole is for another project, please verify and if this is case, remove.

7. Detectable warnings (truncated domes) are required at marked crossings (crosswalks). The area covered by the truncated domes shall be twenty-four (24) inch deep and extend the full width of the crosswalk/ramp.