Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07OT01606
Parcel: 110072800

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - FLOODPLAIN

Permit Number - T07OT01606
Review Name: PLANS OK TO SUBMIT - FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/12/2007 JASON GREEN ENGINEERING REVIEW Approved July 12, 2007
FLOODPLAIN USE PERMIT # T07OT01606
PROJECT ADDRESS: 2720 N Montezuma
APPLICANT'S NAME: Karen DeCook
PROPERTY OWNER: Trey Steinbeck


This parcel is partially located in a FEMA Special Flood Hazard Area (SFHA), Shaded Zone X 100-year floodplain as shown on the Flood Insurance Rate Map (FIRM), Community-Panel No. 040076 C 1643K, effective date February 8, 1999. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:


2720 N Montezuma Ave, Tucson, AZ 85712 in a portion of Township 13 South, Range 14 East, Sections 34, for the purpose of constructing a 275 LF patio wall 7'4" high as shown on the site plan T07BU00979.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.


The following 7 conditions apply to this permit:
1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the configuration of the approved site plan, or if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from constructing the proposed hotel within the mapped regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved Details and site plan sheets, which are made part of this permit.
4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T07OT01606 FOR INFORMATION PLEASE CALL 791-5550."
5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
7) Contractor will need to call for floodplain use permit inspections by Development Services Department Engineering Division Inspection Team (791-5550) prior to and after the construction of the proposed culverts.


This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 07 Day: 12 Year: 2008

APPLICANT/CONTRACTOR: Karen DeCook
ADDRESS: 6180 W Peregrine Way, Tucson, Arizona 85745
PHONE: (520) 743-1337
OWNER: Trey Steinbeck
ADDRESS: 3801 N Swan Rd, Tucson, AZ 85718
PHONE: (520) Not known


SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.