Permit Number: T07OT01539
Parcel: 116213030

Review Status: Active

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T07OT01539
Review Name: RESUBMITTAL - SITE ALL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
08/31/2007 DAVE MANN FIRE REVIEW Approved
09/04/2007 STEVE SHIELDS ZONING HC SITE REVIEW Approved
09/07/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: El Rio Health Center - Congress Parking
T07OT01539
Site Plan (2nd Review)

TRANSMITTAL DATE: September 7, 2007

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and
Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for area of expansion only.

2. This comment was not been fully addressed. Zoning acknowledges the receipt of the Pima County Assessor's approved Combo Request. Please provide the recorded Covenant Regarding Development and Use of Real Property. This project is comprised of six (6) different parcels. There are two (2) options in regards to utilizing the six (6) parcels as one site. Prior to approval of the site plan provide; 1) A Pima County Tax Parcel Combo and a recorded covenant regarding development and use of real property, or 2) Provide a site plan for each parcel that shows how the parcels can stand alone and meet the requirements of the LUC if sold separately along with a recorded covenant regarding development and use of real property.

3. Zoning is willing to provide an over the counter review once all the above comments have been addressed. Please call or email for an appointment.

4. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

I:\planning\site\t07ot01539.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
09/12/2007 ANDREW CONNOR NPPO REVIEW Denied The site does include protected native plants, select the correct option on the NPP application for exception per DS 2-15.2.0
09/12/2007 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. An approved site plan is required indicating how the project will comply with LUC requirements when the MS&R right-of-way can no longer be used as part of the site. Such plan is to be an exhibit to an executed covenant for recordation stating the responsibility of the property owner, successor, or assignee as to the removal of improvements and compliance with the LUC at no cost to the City per LUC 2.8.3.5.F.

2. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4. The screening requirement is in addition to the landscape requirements. The vegetative screen can not be used to meet the landscape requirement. Revise landscape border plant count and calculations as necessary.

3. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1. Additional tree is required for vehicle use area

4. The site does include protected native plants, select the correct option on the NPP application for exception per DS 2-15.2.0

5. Additional comments may apply. See Zoning comment #2 regarding lot combination.
09/27/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
10/08/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approved TO: Frank Mascia, RA , CDG / Metro Permit Express
REVIEWER: Elizabeth Eberbach, PE
ACTIVITY NUMBER: T07OT01539
SUBJECT: 843 W CONGRESS ST Re-submittal Site Plan Review
PARCEL: 116-18-1960, T14S R13E Sec14
LOCATION: portion of lot 10 of BLK 14 within MENLO PARK-MENLO PARK ANNEX. & SMP
WARD: 1

SUMMARY: Engineering Division of Development Services Department has received and reviewed the resubmittal package for the proposed parking lot plan submittal which included a response letter, revised site and landscape plans. No drainage reports were submitted. Engineering Division recommends approval. Call if you have any questions; I can be reached at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2007 ANY REJECT SHELF RECEIVED