Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T07OT01434
Parcel: Unknown

Address:
3941 N TUCSON BL

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T07OT01434
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2007 PATRICIA GILBERT ENGINEERING REVIEW Approved June 25, 2007

FLOODPLAIN USE PERMIT NO.: T07OT01434
RELATED PERMIT NO.: T07CM02098
ADDRESS: 3941 North Tucson Blvd.
APPLICANT: Christen Bilow


1. This permit is for the purpose of a Sales Trailer installation within a mapped Special Flood Hazard Area (SFHA), Zone AE, as shown on the Flood Insurance Rate Map (FIRM), Community Panel No. 040076-04019C-1643K, effective date February 8, 1999.

2. The proposed structure is impacted by the regulatory floodplain. For purposes of this permit, the following elevation requirements apply:

Base Flood Elevation (BFE) = 2355.17 feet per the North America Vertical Datum (NAVD '88)
Regulatory Flood Elevation (RFE) = 2356.17 feet per the North America Vertical Datum (NAVD '88)

The bottom of the lowest structural member and all attached equipment of the manufactured home must be elevated to the Regulatory Flood Elevation (RFE). The manufactured home must be placed on a permanent foundation (with anchoring) that meets the requirements of permanent foundations as defined by the U.S. Department of Urban Development (HUD) and the Federal Housing Administration (FHA). All service utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), must be elevated to the Regulatory Flood Elevation (RFE). An Elevation Certificate completed and certified by an Arizona Registered Land Surveyor or Arizona Registered Professional Civil Engineer must be returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 N. Stone Avenue prior to any final inspection.

3. Certification by a state registered professional civil engineer that the installation of the home meets all the requirements of Chapter 26 Section 9 of the Tucson City Code is required.

4. Any additional improvements, including block walls, fences or pools, will require a separate Floodplain Use Permit prior to construction.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/26/2007 CINDY AGUILAR OUT TO CUSTOMER Completed