Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07MH00042
Parcel: 118100650

Review Status: Completed

Review Details: MOBILE HOME

Permit Number - T07MH00042
Review Name: MOBILE HOME
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/17/2007 MICHAEL ST. PAUL ZONING REVIEW Approved
04/17/2007 MICHAEL ST. PAUL NPPO REVIEW Passed
04/19/2007 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Approved
05/14/2007 JASON GREEN ENGINEERING REVIEW Approved DATE: May 14, 2007
SUBJECT: 2640 S Cottonwood Lane Lot #45- Placement Manufactured Home
TO: Jesus Badillo
LOCATION: T14S R13E Sec26, Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: T06MH00042 (Site Plan) and T07OT00927 (Floodplain Use Permit)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the submitted Site Plan (T06MH00042) and Floodplain Use Permit (T07OT00927) for the above referenced property and recommends approval of the Site Plan and Floodplain Use Permit at this time.

The subject property is entirely located within a Shaded Zone X 500-year floodplain as shown on the Flood Insurance Rate Map (FIRM), Community- Panel No. 040073-04019C-2228K, effective date February 8, 1999. It is recommended that a flood insurance policy be obtained for a building located within the 500-year floodplain.

The proposed manufactured home replacement is located within an existing manufactured home park, as defined in The Floodplain and Erosion Hazard Management Ordinance, Chapter 26 of the Tucson Code (Ordinance), and is exempt from the requirement of placing the manufactured home replacement on a permanent foundation. It is recommended however the placement of the manufactured home located in the floodplain be elevated such that the bottom of the structural frame or the lowest point of any attached appliances, whichever is lower, is above the regulatory flood elevation (one foot higher than the calculated water surface elevation of the base flood). The manufactured home must be securely anchored. Certification by a state-registered professional civil engineer that the installation of the manufactured home meets all the requirements of Section 26-9 of the Ordinance is required.

For purposes of this permit the following flood elevations shall be used:

The manufactured home can be set at the existing pad elevation of 2383.5 ft. However it is recommended that the lowest structural frame of the manufactured home and any attached appliance be elevated a minimum 1.f feet above highest adjacent grade.


If you have any questions, I can be reached at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
05/16/2007 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
05/17/2007 SUE REEVES APPROVAL SHELF Completed
05/17/2007 GERARDO BONILLA OUT TO CUSTOMER Completed