Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM04718
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/17/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Activity: T07CM04718 Date: 1/18/08 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. I. GENERAL REQUIREMENTS: " Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. II. FLOOR PLANS: " Verify on the plan the installation of a window in the new bathroom in lieu of a mirror. III. FOUNDATION PLANS: " Specify the elevation height of the porch slab. IV. STRUCTURAL PLANS: " If the new structure is to be continuously sheathed, provide a note that specifies compliance to R602.10.5. " Provide an attic space ventilation calculation and note the size and location of all attic vents needed to comply, R806.2. " Provide a minimum opening of 22" by 30" for access and ventilation between over-framed assemblies (>30 S.F.), R807. V. SECTIONS - DETAILS: " Specify the size and provide a detail for the lintel installation over the new doorway to be installed in the existing masonry wall. " Provide a detail for the ledger connection of the porch roof to the house including fastener and hardware information. " Specify the stucco weep screed height above paved areas. " Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. VI. PLUMBING PLAN: " Provide a developed length of water line from the meter the furthest appliance served, consistent with the distances and utility location on the site plan, UPC Table 6-6. " Specify the hot water line return from the new water heater location. " Clarify the purpose of the 3" drain line to the linen closet VII. MECHANICAL PLAN: " Verify that a permit was obtained for the 'existing 5-ton' unit, or include the unit specifications for this permit. " Show dryer vent size and location for venting to exterior (max 25' w/bend reductions), M1502.2, M1502.6. If you have any questions please contact: Clayton Trevillyan (520) 837-4913 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/22/2008 | THAUSER1 | OUT TO CUSTOMER | Completed |
| 01/22/2008 | GERARDO BONILLA | REJECT SHELF | Completed |