Permit Number: T07CM04704
Parcel: 10712175B

Address:
2940 N ORACLE RD

Review Status: Completed

Review Details: SITE

Permit Number - T07CM04704
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/20/2008 DAVE MANN FIRE REVIEW Approved
03/03/2008 HEATHER THRALL ZONING REVIEW Denied TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: T07CM04704, 2940 N. Oracle Road, New Office/Retail
Commercial Site plan, 1st review

TRANSMITTAL DATE: March 3, 2008

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This project was reviewed for compliance with the Land Use Code (LUC), Development Standards (DS), American National Standards Institute (ANSI), Tucson City Code 20-222, and International Building Code 2006 (IBC). Specifically, this project was reviewed for site plan content specified in DS 2-02.

2. Per DS 2-02.2.1.2, the Assessor's maps show that several lot lines have been moved or split regarding this property and adjacent properties. Please provide documentation that the city reviewed these lot changes and approved them.

3. Per DS 2-02.2.1.5, please provide the dimension of the south property line.

4. Per DS 2-02.2.1.6, regarding buildings:
A) please declare the type of roof
B) please declare how you are measuring building height - please note that building height for zoning is measured from finished grade to the top of a flat roof - then provide parapet height. Or from finished grade to midpoint of a gable - then declare peak height.
C) Please call out any roof overhangs/awnings/porches in a dashed line and declare vertical clearance
D) Please provide a north/south -length wise -dimension for the 2nd story - for permits

5. Per DS 2-02.2.1.7 - regarding setbacks:
A) please call out the travel lane location for Blacklidge Drive, call out any parking lane as well please.
B) For records, please add notes to the building setbacks that state the "minimum required building setback from the back of the future curb of Miracle Mile is the greater of 21' or the height of the exterior building wall". And add "minimum building setback from the travel lane of Blacklidge is 21' or the height of the exterior building wall."
C) Please keep in mind that the wall heights for setbacks are measured from grade, thus your setback notes may change on the resubmittal if you've noted it from finished floor.
D) I do acknowledge the building meets setbacks.

6. Per DS 2-02.2.1.8, regarding parking: LUC 3.3.4. under retail and office uses:
A) parking for retail uses are 1:200 ratio, please correct on the calculations
B) please list the two uses out separately in the parking calculations - retail and office
C) please indicate that office on the first floor is 1:200 ratio for parking, whereas office on the 2nd floor is permitted to be reduced to 1:250 ratio for parking.
D) Per the square footages you provided, it appears the development needs more parking spaces than provided. I calculated a need of 44 spaces, with 42 provided.
E) On sheet 2, parking detail 9, please relocate the truncated domes. They need to be placed on the concrete in a two foot wide strip - where the concrete transitions to the asphalt access aisle.
F) I acknowledge all other parking aspects are designed to code, thank you.

7. Per DS 2-02.2.1.9, regarding bicycle parking
A) the increase in parking spaces that should occur for the development will then translate into needing an additional bicycle parking space. Revisit calculation as well please.
B) DS 2-09.4.1 requires that class 2 bike parking is provided within 50 to the main entrance(s) to the building. Given that we have multiple tenants here, it is a necessity to disperse the bicycle parking more evenly at each end of the front of the building to allow each tenant to have a bicycle space within 50' of their entrance.
C) I acknowledge the design of the bicycle parking spaces meets code, thank you.

8. Per DS 2-02.2.1.11, regarding PAALs:
A) please provide a minimum 24' wide PAAL dimension from the curb near the bicycle parking spaces to the vehicle parking space diagonally to the northwest.
B) Please provide dimensions for the back up spurs at both the north and south ends of the parking lots, ensuring at least 3' back up spur is provided on each side, DS 3-05.

9. Per DS 2-02.1.12 regarding handicapped and pedestrian access:
A) Per DS 2-08.3.1, pedestrian access to the USE of the dumpster is required. I see the sidewalk leading to the back side of the dumpster, however, pedestrian access to actually use the dumpster at the front is not provided. Perhaps a gate at the back of the dumpster will assist, or provide a protected pedestrian accessible route to the front of the dumpster. Ensure any gate is 4' wide to meet DS 2-08 - and ensure that engineering standards on the dumpster enclosure requirements are met.

10. Per DS 2-02.2.1.13, please call out any free-standing signage with specifications.

11. Per DS 2-02.2.1.20, please ensure all easements are depicted graphically, and ensure recordation information is provided with docket and page reference.

12. Per DS 2-02.2.1.25. please show any free-standing lighting with vertical clearances if near vehicular use areas.

13. Per DS 2-02.2.2.A.3, please provide the Floor Area Ratio calculation, rather than a lot coverage calculation.

14. Please note that further comments may be forthcoming, depending upon responses provided. I may be reached at Heather.Thrall@tucsonaz.gov or 837-4951.


If you have any questions about this transmittal, please call (520) 791-5608.

HCT C:\planning\site\DSD\T07CM04704 2940 N Oracle.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan
03/04/2008 HEATHER THRALL ZONING HC SITE REVIEW Denied Please see zoning comments.
03/04/2008 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Provide acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property Protected Native Plants are not located on the subject site. Photographs of the site are necessary for NPPO approval per DS 2-15.2.0.C.

2. Additional changes may be necessary. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.
03/05/2008 ANDREW CONNOR NPPO REVIEW Denied 1. Provide acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property Protected Native Plants are not located on the subject site. Photographs of the site are necessary for NPPO approval per DS 2-15.2.0.C.
03/11/2008 JASON GREEN ENGINEERING REVIEW Denied DATE: March 12, 2008
SUBJECT: 2940 N Oracle Site Plan- Engineering Review
TO: Peter Salonga, P.E.
LOCATION: T13S R13E Sec36 Ward 3
REVIEWERS: Jason Green, CFM
ACTIVITY: T07CM04704 (Site Plan)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the site plan (T07CM04704) and Storm Drainage Statement (Oracle Engineering Group, Inc, 13DEC07) for the above referenced property. Engineering Division does not recommend approval of the site plan application at this time. The following items need to be addressed:


SITE PLAN COMMENTS:

1) Revise the site plan to remove the reference to #07-015 and to provide the site plan number (T07CM04704) on the lower right hand corner of the plan sheet.

2) DS Sec.2-02.2.1.A.5: Provide the recordation information with the approved lot reconfiguration for the subject parcel. The Zoning Department prior to site plan approval must approve all lot reconfiguration.

3) DS Sec.2-02.2.1.A.8: Revise the site plan and detail to accurately dimension all planting areas that are within the vehicular use area. Refer to DS Sec.2-06.3.3.C and Figure 3 under DS Sec.3-05 for square footage and minimum width/radii requirements.

4) DS Sec.2-02.2.1.A.8: Revise the site plan to dimension wheel stop barriers within the parking spaces located along any adjacent landscape areas and/or pedestrian circulation paths. The barriers are to be set at 15.5-feet to accommodate the required 2.5-foot overhang to prevent encroachment or damage to the proposed landscape area and/or the required clear 4-foot pedestrian path.

5) DS Sec.2-02.2.1.A.8: Revise the dimensioned radii for all areas of the parking lot to meet the minimum requirements for PAAL intersections and PAAL curvatures per DS Sec.3-05.2.1. Specifically all radii located within the PAALs must be a minimum of 5-feet except where used for fire or refuse access then the radii must be 18-feet, revise accordingly.

6) DS Sec.2-02.2.1.A.8: Revise the site plan to provide dimensions for both proposed back-up spurs with a minimum of 3 feet in depth, a 3-foot radius, and a 3 foot separation between curb and any proposed pedestrian circulation, walls or unsurfaced areas. Refer to DS Sec.3-05.2.2.D for clarification.

7) DS Sec.2-02.2.1.A.8: Provide a detail or dimension on the site plan all parking spaces proposed including the required handicap spaces. Refer to Table 1 within DS Sec.3-05 for further clarification.

8) DS Sec.2-02.2.1.A.8: Revise the site plan to dimension the minimum 24-foot PAAL widths at all locations on the site plan. Specifically for the PAAL adjacent to the refuse container location and for the PAAL adjacent to the landscape planter on the northwest corner of the building.

9) DS Sec.2-02.2.1.A.10: Revise the site plan and the proposed sight visibility triangles to be drawn at the correct future curb location. Verify that all dimensions meet the requirements within DS Sec.3-01.5.1.

10) DS Sec.2-02.2.1.A.12: Revise the site plan to show the location of all proposed scuppers under the sidewalk for roof drainage. Provide separate details for the scuppers showing the standard detail number for public improvements required meeting these requirements in order to convey the 10-year flow under the pedestrian circulation. Specifically for the scupper locations along the east side of the building per the Storm Drainage Statement.

11) DS Sec.2-02.2.1.A.12: Revise the site plan and detail 10 to correctly show the construction of the proposed handicap access ramp. Revise the plan to show that all proposed handicap access ramps meet the design requirements per ANSI Standards A117.1-2003 Section 406.13. The keynote call out references Standard Detail #207, however the detail provided, #10, does not meet the requirements within this section, revise.

12) DS Sec.2-02.2.1.A.12: Revise detail #9 for the required handicap ramp to show the truncated domes located at the transition from pedestrian circulation to vehicular use area. The detail does not meet the minimum requirements for truncated dome locations as shown.

13) DS Sec2-02.2.1.A.12: Revise the site plan to provide the required 6-foot wide sidewalk along the street frontage of Oracle Road. Per the adopted Mayor and Counsel policy all sidewalks along MS&R right-of-ways for arterial and collector streets require 6-foot wide sidewalks. If an existing sidewalk is already constructed along the frontage of Oracle Road provide photo documentation showing that the existing sidewalk is in good condition. If the sidewalk is missing in spots or is cracked and buckled a new 6-foot sidewalk will be required. A DSMR will be required for modifying the development standards to allow a sidewalk that does not meet the minimum 6-foot width requirements along Oracle Road. The DSMR must be approved prior to site plan approval. All exhibits and discussion must reflect any changes made by the approved DSMR. Provide a General Note to list the DSMR number, the Development Standard being modified along with the date of DSMR approval.

14) DS Sec.2-02.2.1.A.12: Revise the site plan to label and dimension the required 5-foot sidewalk along the street frontage of Blacklidge Drive. Per DS Sec.3-01.3.3.A all new development requires the construction of curb and 5-foot sidewalk along local street frontage.

15) DS Sec.2-02.2.1.A.12: Revise the site plan to provide the required pedestrian circulation path from the proposed buildings to the refuse enclosure. Revise the refuse container to provide a gate for pedestrian access.

16) DS Sec.2-02.2.1.A.14: Provide (label and dimension) the required onsite maneuvering areas for the required loading zone that is shown on the site plan. Refer to AASHTO for the national standards for turning radii. All radii must be shown to scale.

17) DS Sec.2-02.2.1.A.16: Provide the Improvement Plan reference for the existing catch basin and storm drain located along Blacklidge Drive. All existing drainage improvements that are shown on the site plan must have the referenced improvement plan for site verification.

18) DS Sec2-02.2.1.A.17: A grading plan application will be required due to the cut and fill quantities shown on the site plan.

19) DS Sec.2-02.2.1.A.19: Provide a letter of approval from Arizona Department of Transportation for the proposed improvements along Oracle Road, specifically for the number of and location of both proposed driveways along the state route. This project must show that it is in conformance with the Development Standards and the requirements for ADOT. Contact Steve Spear, Senior Permit Technician for ADOT review of the site plan. Sspears@adot.gov or (520)-838-2983.

20) DS Sec.2-02.2.1.A.19: Revise the driveway entrance point on the south side of the parcel to meet the minimum 80-foot requirement between adjacent driveways. Verify the required 80-foot separation per the Tucson Access Management Guidelines for the neighboring parcels driveway to the proposed driveway access on the subject parcel.

21) DS Sec.2-02.2.1.A.19: Provide the recordation information for both Oracle Road and Blacklidge Drive.

22) DS Sec2-02.2.1.A.19: Revise the site plan to label and dimension the right-of-way for Blacklidge Drive to verify curb and sidewalk locations.

23) DS Sec.2-01.2.1.A.20: Revise the site plan to provide the recordation information and width for all existing easements that are drawn on the site plan, specifically the drainage easement along the south portion of the parcel.

24) DS Sec.2-01.2.1.A.21: Revise the dimensions from the street monument lines to the dimensioned future curb and 6-foot sidewalk location. Per the MS&R maps roads with right-of-ways that equal 150-feet must have a future curb and sidewalk area that is a minimum 12-foot in width.

25) DS Sec.2-02.2.1.A.32: Revise the site plan and detail #8 to show that the refuse enclosure meets the minimum requirements of DS Sec.6-01. Refer to Figure 3 (attached to the hard copy of this letter) and DS Sec.6-01.4.2 for specifications and requirements on access, placement of containers, bin enclosure and construction.

26) DS Sec.2-02.2.1.A.32: Revise the site plan to provide the maneuverability (label and dimension turning radii in plan view) for refuse vehicles for the refuse location shown in plan view. Verify that the refuse vehicle has the required 14-foot x 40-foot clear approach and the required 40-foot back-up distance for the refuse container location proposed.

27) DS Sec.11-01.9: Revise the site plan and details 1 and 2 to provide the required 2-feet setback from all property boundaries to the proposed limits of grading, fill slopes, block wall and any associated erosion protection. The detail view on the site plan shows that the limits of grading encroach within the required 2-feet setback for the retaining wall and erosion protection along both the north and east property line, revise.

28) Review and approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Refer to the following links for TDOT Forms and applications:

a) http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/applications.html /

b) http://www.dot.ci.tucson.az.us/engineering/pia.php

c) Or contact Thad Harvison at 837-6592 for all additional questions regarding r-o-w.

29) Be advised that further comments may be forth coming on resubmittal of the site plan.


GENERAL COMMENTS:

Please provide a revised site plan that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Enclose "redlines" with the resubmittal package.

Further comments may be generated upon resubmittal of the site plan review.

If you have any questions or to schedule an appointment I can be reached at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services

Final Status

Task End Date Reviewer's Name Type of Review Description
07/11/2008 CPIERCE1 OUT TO CUSTOMER Completed
07/11/2008 SHANAE POWELL REJECT SHELF Completed