Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T07CM04647
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/03/2008 | HEATHER THRALL | ZONING | REVIEW | Denied | TO: Development Services Department, Plans Coordination Office FROM: Heather Thrall, Senior Planner PROJECT: T07CM04647, 2320 E. Aragon less than 25% expansion of parking area 1st Review, Commercial Site plan TRANSMITTAL DATE: March 26, 2008 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This project was reviewed for compliance with the Land Use Code (LUC), Development Standards (DS), American National Standards Institute (ANSI), and International Building Code 2006 (IBC). In addition, the project was reviewed for compliance with site plan criteria of DS 2-02. 2. This project consists of an expansion of land and vehicle use area to an existing business that provides long term parking of vehicles for airport customers. The expansion is not full code compliance for the entire site, per the Zoning Administrator. The existing business classification is "parking", per the Zoning Administrator's determination February 28, 2008. (Also note, per the Board of Adjustment decision notice dated 11/17/04, canopy trees are not required to be within the airport parking area.) 3. Per DS 2-02.2.1.8, regarding required parking: A) Delineate required parking for building off of Tucson Blvd., versus airport parking B) Note number of provided spaces for airport parking C) Note number of required & provided handicapped parking spaces in airport parking. D) Post signs in front of ALL handicapped spaces -illegal parking fines $518.00 TCC 20 4. Per DS 2-02.2.1.11, regarding PAALs: A) provide a minimum of 24' clear two way PAALs to circulate to all parking areas B) provide circulation arrows for one way or two way at ends of parking aisles C) review LUC 3.3.4 diagram for PAAL widths to 90 parking - need 24' D) give 2'PAAL setback from fence & property line, DS 3-052.2.B.3 -new parking area E) provide and dimension back up spur in new parking for parking space at far southwest 5. Per DS 2-02.2.1.20, call out any easements, with recordation notes. 6. Per DS 2-02.2.1.25, please call out any proposed/existing free-standing lighting with vertical clearance for vehicle passage underneath, and base pole width. 7. As these lots are to function as one site, please combine the lots and also record a lot combination covenant ensuring that they will remain functioning as one site. 8. Please place a note on the plan that states "This project shall comply with regulations of the Airport Environs Overlay Zone, LUC 2.8.5, specifically the Airport Hazard District and Noise Control District 65." 9. Please note that further review comments may be forthcoming, depending upon the responses provided. I may be reached at Heather.Thrall@tucsonaz.gov or at 837-4951. HCT C:\planning\site\DSD\T07CM04647 2320 E. Aragon.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 04/04/2008 | PETER MCLAUGHLIN | NPPO | REVIEW | Denied | Refer to DS 9-06.2.5.B.1.a though .x for all required elements of the Environmental Resource Report. Some of these items were omitted from the submitted ERR. Revise as necessary to be complete. |
| 04/04/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Approved | |
| 04/15/2008 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Needs Review | Engineering review will take place after resubmittal of revised plans to address all prior engineering comments. - EE |
| 04/16/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved |