05/12/2008 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Edmund Marquez - Suzuki Dealership Expansion
T07CM04510
Site Plan (3rd Review)

TRANSMITTAL DATE: May 12, 2008

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance due to a greater than twenty-five (25) percent expansion of building area.

The following comments are in regards to sheet AS102.

1. The recorded Covenant Regarding Development and Use of Real Property does not have the Case No. "T07CM04510", listed on the document. Also this document needs to be signed by both owners as there are two different owners involved. Zoning acknowledges that it was agreed that a recorded Covenant Regarding Development and Use of Real Property would meet the requirements of this comment and acknowledges that a note has been added to the plan in regards to the recorded document. Provide a copy of the recorded document along with a copy of the Assessors receipt. D.S. 2-02.2.1.A.5 It appears that this project is comprised of four (4) different parcels. There are two (2) options in regards to utilizing the four (4) parcels as one site. Prior to approval of the site plan provide; 1) A Pima County Tax Parcel Combo and a recorded covenant regarding development and use of real property, or 2) Provide a site plan for each parcel that shows how the parcels can stand alone, if sold separately, and meet the requirements of the LUC if sold separately along with a recorded covenant regarding development and use of real property. Also once the parcels have been combined the lot dimensions should reflect the overall distance along each property line.

2. Zoning acknowledges that a horizontal dimension was provided for the existing and proposed building. Zoning was not able to locate the required vertical dimensions please provide. D.S. 2-02.2.1.A.6 Provide overall dimensions and label the height for both the existing and proposed buildings on site. Also if applicable show and label and overhangs and canopies.

3. The following comment was not addressed. Provide a dimension from the back of future curb to the proposed addition. Zoning acknowledges the building setbacks shown on the plan. The building setback shown to Irvington Road is shown incorrectly. Per LUC Section 3.2.6.5.B and Table 3.2.6-I ADT of a 1000 or greater the required setback is measured from the back of future curb. Show the future curb on the plan and dimension the building setback from the back of future curb. D.S. 2-02.2.1.A.7 Provide all zoning setbacks on the plan. It does not appear that the proposed building, based on a 16' height, meets the requirement of a 1-1/2 times the height of the building setback.

4. The 10'-0" accessible vehicle parking space and a 5'-0" access aisle does not meet the requirements of ICC/ANSI A117.1-2003 Sec. 502.2. The van accessible vehicle parking space and access aisle can be either a 132 inch (11'-0") parking space with a 60 inch (5'-0") access aisle or a 96 inch (8'-0") parking space with a 96 inch (8'-0") access aisle. Per D.S. 3-05.2.3.C.2. when wheel stop curbing is used, it is to be located two and one-half (2½) feet from the front of the parking space. (See Figure 5.) The provided dimension shown is 1'-8". The ADA parking space and access aisle detail does not meet the requirement for and van accessible vehicle parking space. Per ICC/ANSI A117.1-2003 Sec. 502.2 the van accessible vehicle parking space and access aisle can be either a 132 inch parking space with a 60 inch access aisle or a 96 inch parking space with a 96 inch access aisle. Per ICC/ANSI A117.1-2003 Sec. 502.5, show the 1:48 maximum slopes for the handicapped vehicle parking space and the access aisle on the handicapped parking space detail. For both parking space details provide a dimension for the wheel spot per D.S. 3-05.2.3.C.2. D.S. 2-02.2.1.A.8 Provide a typical parking space detail for both handicapped and standard parking spaces.

5. Zoning acknowledges that future SVT's are shown on the plan but they are not shown correctly. The side of the SVT that runs parallel to the street center-line should line up with the edge of future curb. D.S. 2-02.2.1.A.10 Provide future sight visibility triangles (SVT's) on the plan.

6. Zoning acknowledges that ROW dimensions have been provided for all ROW's. The provided ROW dimension shown for 13th Avenue is shown measured from the centerline of the street to a spot is space. This dimension should be from the centerline of the street to the adjacent property line. D.S. 2-02.2.1.A.19 Provide dimensions for all ROWs on the plan, include future ROW is applicable.

7. This comment has not been addressed. D.S. 2-02.2.1.A.5 Due to the fact that you have elected not to combine all lots and use the Covenant Regarding Development and Use of Real Property, show all lot dimension and bearing for all lots on the plan.

The following comments are for sheet AS103. It appears that is a future site plan where the three parcels (120-08-773A, 120-08-7750, 120-08-7760) have been sold and not available for development.

1. This comment was not addressed. D.S. 2-02.2.1.A.5 Provide the lot dimension and bearing for the west lot line.

2. This comment was not fully addressed. Zoning acknowledges that a horizontal dimension was provided for the existing and proposed building. Zoning was not able to locate the required vertical dimensions please provide. D.S. 2-02.2.1.A.6 Provide overall dimensions for both the existing and proposed buildings.

3. The following comment was not addressed. Provide a dimension from the back of future curb to the proposed addition. D.S. 2-02.2.1.A.7 Zoning acknowledges the building setbacks shown on the plan. The building setback shown to Irvington Road is shown incorrectly. Per LUC Section 3.2.6.5.B and Table 3.2.6-I ADT of a 1000 or greater the required setback is measured from the back of future curb. Show the future curb on the plan and dimension the building setback from the back of future curb.

4. The 10'-0" accessible vehicle parking space and a 5'-0" access aisle does not meet the requirements of ICC/ANSI A117.1-2003 Sec. 502.2. The van accessible vehicle parking space and access aisle can be either a 132 inch (11'-0") parking space with a 60 inch (5'-0") access aisle or a 96 inch (8'-0") parking space with a 96 inch (8'-0") access aisle. D.S. 2-02.2.1.A.8 The ADA parking space and access aisle detail does not meet the requirement for a van accessible vehicle parking space. Per ICC/ANSI A117.1-2003 Sec. 502.2 the van accessible vehicle parking space and access aisle can be either a 132 inch (11'-0") parking space with a 60 inch(5'-0") access aisle or a 96 inch (8'-0") parking space with a 96 inch (8'-0") access aisle.

5. This comment has not been addressed correctly. Per D.S. 3-05.2.3.C.2. when wheel stop curbing is used, it is to be located two and one-half (2½) feet from the front of the parking space. (See Figure 5.) The provided dimension shown is 1'-8". D.S. 2-02.2.1.A.8 For both parking space details provide a dimension for the wheel spot per D.S. 3-05.2.3.C.2.

6. Zoning acknowledges that future SVT's are shown on the plan but they are not shown correctly. The side of the SVT that runs parallel to the street center-line should line up with the edge of future curb. D.S. 2-02.2.1.A.10 Show the future sight visibility triangles on the plan.

7. Zoning acknowledges that ROW dimensions have been provided for all ROW's. The provided ROW dimension shown for 13th Avenue is shown measured from the centerline of the street to a spot is space. This dimension should be from the centerline of the street to the adjacent property line. D.S. 2-02.2.1.A.19 Provide dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way on the site plan.

The following comments are for sheet AS104. It appears that is a future site plan where the future right of way has been taken.

1. This comment has not been addressed. D.S. 2-02.2.1.A.5 Due to the fact that you have elected not to combine all lots and use the Covenant Regarding Development and Use of Real Property, show all lot dimension and bearing for all lots on the plan.

2. D.S. 2-02.2.1.A.5 The future south property line is not shown correctly. On the west end it does not connect to the west property line and on the east end it extends beyond the east property line. Also as this plan shows the future ROW remove the property line that is now shown within the ROW.

3. This comment was not fully addressed. Zoning acknowledges that a horizontal dimension was provided for the existing and proposed building. Zoning was not able to locate the required vertical dimensions please provide. D.S. 2-02.2.1.A.6 Provide overall dimensions for both the existing and proposed buildings.

4. The following comment was not addressed. Provide a dimension from the back of future curb to the proposed addition. D.S. 2-02.2.1.A.7 Show the building setback to Irvington Road. Per LUC Section 3.2.6.5.B and Table 3.2.6-I ADT of a 1000 or greater the required setback is measured from the back of future curb. Show the future curb on the plan and dimension the building setback from the back of future curb.

5. The 10'-0" accessible vehicle parking space and a 5'-0" access aisle does not meet the requirements of ICC/ANSI A117.1-2003 Sec. 502.2. The van accessible vehicle parking space and access aisle can be either a 132 inch (11'-0") parking space with a 60 inch (5'-0") access aisle or a 96 inch (8'-0") parking space with a 96 inch (8'-0") access aisle. D.S. 2-02.2.1.A.8 The ADA parking space and access aisle detail does not meet the requirement for and van accessible vehicle parking space. Per ICC/ANSI A117.1-2003 Sec. 502.2 the van accessible vehicle parking space and access aisle can be either a 132 inch parking space with a 60 inch access aisle or a 96 inch parking space with a 96 inch access aisle. Per ICC/ANSI A117.1-2003 Sec. 502.5, show the 1:48 maximum slopes for the handicapped vehicle parking space and the access aisle on the handicapped parking space detail.

6. This comment has not been addressed correctly. Per D.S. 3-05.2.3.C.2. when wheel stop curbing is used, it is to be located two and one-half (2½) feet from the front of the parking space. (See Figure 5.) The provided dimension shown is 1'-8". D.S. 2-02.2.1.A.8 For both parking space details provide a dimension for the wheel spot per D.S. 3-05.2.3.C.2.

7. Zoning acknowledges that future SVT's are shown on the plan but they are not shown correctly. The side of the SVT that runs parallel to the street center-line should line up with the edge of future curb. D.S. 2-02.2.1.A.10 Show the future sight visibility triangles on the plan.

8. Zoning acknowledges that ROW dimensions have been provided for all ROW's. The provided ROW dimension shown for 13th Avenue is shown measured from the centerline of the street to a spot is space. This dimension should be from the centerline of the street to the adjacent property line. D.S. 2-02.2.1.A.19 Provide dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way on the site plan.

9. There is a heavy dashed line shown north of the ROW line along Irvington Road and south of the proposed curbing along the vehicle display area on site, please clarify what this line is.

10. There is what appears to be an existing sign but site note 14 calls it out as a "SIDEWALK RAMP, E15/AS104", please clarify what this item is.

The following comments are for sheet AS105. It appears that is a future site plan where the three parcels (120-08-773A, 120-08-7750, 120-08-7760) have been sold and not available for development and the future right of way has been taken.

1. This comment was not addressed. D.S. 2-02.2.1.A.5 Provide the lot dimension and bearing for the west lot line.

2. D.S. 2-02.2.1.A.5 The future south property line is not shown correctly. On the west end it does not connect to the west property line and on the east end it extends beyond the east property line. Also as this plan shows the future ROW remove the property line that is now shown within the ROW.

3. This comment was not fully addressed. Zoning acknowledges that a horizontal dimension was provided for the existing and proposed building. Zoning was not able to locate the required vertical dimensions please provide. D.S. 2-02.2.1.A.6 Provide overall dimensions for both the existing and proposed buildings.

4. The following comment was not addressed. Provide a dimension from the back of future curb to the proposed addition. D.S. 2-02.2.1.A.7 Zoning acknowledges the building setbacks shown on the plan. The building setback shown to Irvington Road is shown incorrectly. Per LUC Section 3.2.6.5.B and Table 3.2.6-I ADT of a 1000 or greater the required setback is measured from the back of future curb. Show the future curb on the plan and dimension the building setback from the back of future curb.

5. The 10'-0" accessible vehicle parking space and a 5'-0" access aisle does not meet the requirements of ICC/ANSI A117.1-2003 Sec. 502.2. The van accessible vehicle parking space and access aisle can be either a 132 inch (11'-0") parking space with a 60 inch (5'-0") access aisle or a 96 inch (8'-0") parking space with a 96 inch (8'-0") access aisle. D.S. 2-02.2.1.A.8 The ADA parking space and access aisle detail does not meet the requirement for a van accessible vehicle parking space. Per ICC/ANSI A117.1-2003 Sec. 502.2 the van accessible vehicle parking space and access aisle can be either a 132 inch (11'-0") parking space with a 60 inch(5'-0") access aisle or a 96 inch (8'-0") parking space with a 96 inch (8'-0") access aisle.

6. This comment has not been addressed correctly. Per D.S. 3-05.2.3.C.2. when wheel stop curbing is used, it is to be located two and one-half (2½) feet from the front of the parking space. (See Figure 5.) The provided dimension shown is 1'-8". D.S. 2-02.2.1.A.8 For both parking space details provide a dimension for the wheel spot per D.S. 3-05.2.3.C.2.

7. Zoning acknowledges that future SVT's are shown on the plan but they are not shown correctly. The side of the SVT that runs parallel to the street center-line should line up with the edge of future curb. D.S. 2-02.2.1.A.10 Show the future sight visibility triangles on the plan.

8. This comment has not been addressed. Site note 12 calls out "SIDEWALK RAMP, DETAIL E15/A105, detail E15 does not exist on sheet A105. D.S. 2-02.2.1.A.12 The proposed handicapped parking space, access aisle and access ramp shown on the site plan does not match the detail provided, please clarify.

9. Zoning acknowledges that ROW dimensions have been provided for all ROW's. The provided ROW dimension shown for 13th Avenue is shown measured from the centerline of the street to a spot is space. This dimension should be from the centerline of the street to the adjacent property line. D.S. 2-02.2.1.A.19 Provide dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way on the site plan.

10. There is a heavy dashed line shown north of the ROW line along Irvington Road and south of the proposed curbing along the vehicle display area on site, please clarify what this line is.

11. Site note 18 "EXISTING MONUMENT SIGN ….". Add "TO BE RELOCATED" to this note.

12. Ensure all changes to the site plan are reflected on the landscape plan.

13. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t07cm04510-3rd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
05/15/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. The loading zone must be screened from adjacent rights-of-way and residentially zoned properties with a 6-foot high masonry wall per LUC Table 3.7.2-I. The 6-foot masonry screen wall used to screen the dumpster as shown on sheet L-1 must extend farther to the east to serve as a screen for the loading zone. In addition, show and label required screening from the streets for the loading zone on sheet L-1 (for both Irvington Road and 13th Ave) and on sheet L1fw (for Irvington Road only) . DS 2-07.2.2.A.3

2. Enlarge the location maps in the upper right hand corner of all landscape sheets to be the correct required scale as stated (3"= 1 mile), correct the Section, Township and Range numbers and revise the section corners to be located correctly in the location maps.

3. The canopy tree calculation is incorrect for the interior landcsape border along the north property line. Canopy trees are required at 1 per 33 linear feet of landscape border or fraction thereof. With 575 feet of interior landscape border 18 trees would normally be required per LUC 3.7.2.4. However, this calculation can be removed from the plan because interior landcape borders are not required where an alley, drainageway, or other right-of-way ten (10) feet or more in width physically separates the site from an adjacent property as is the case along the north site property line. LUC 3.7.2.4.C.3.b

4. The area between the right-of-way line and sidewalk and the area between the sidewalk and the curb, if not covered with vegetation, shall be covered with an appropriate inorganic ground cover, such as decomposed granite. Indicate treatment within the right-of-way with labels on the landsape plans. LUC 3.7.2.4.A.4
05/19/2008 RONALD BROWN ZONING HC SITE REVIEW Denied ZONING ACCESSIBILITY COMMENTS OF 12 MAY 2008 ARE APPLICABLE
4. The 10'-0" accessible vehicle parking space and a 5'-0" access aisle does not meet the requirements of ICC/ANSI A117.1-2003 Sec. 502.2. The van accessible vehicle parking space and access aisle can be either a 132 inch (11'-0") parking space with a 60 inch (5'-0") access aisle or a 96 inch (8'-0") parking space with a 96 inch (8'-0") access aisle. Per D.S. 3-05.2.3.C.2. when wheel stop curbing is used, it is to be located two and one-half (2½) feet from the front of the parking space. (See Figure 5.) The provided dimension shown is 1'-8". The ADA parking space and access aisle detail does not meet the requirement for and van accessible vehicle parking space. Per ICC/ANSI A117.1-2003 Sec. 502.2 the van accessible vehicle parking space and access aisle can be either a 132 inch parking space with a 60 inch access aisle or a 96 inch parking space with a 96 inch access aisle. Per ICC/ANSI A117.1-2003 Sec. 502.5, show the 1:48 maximum slopes for the handicapped vehicle parking space and the access aisle on the handicapped parking space detail. For both parking space details provide a dimension for the wheel spot per D.S. 3-05.2.3.C.2. D.S. 2-02.2.1.A.8 Provide a typical parking space detail for both handicapped and standard parking spaces.