Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM04510
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/31/2008 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | Impact Fee's Do Apply; West District; 3,150 Square Foot Addition; $12,895.70 |
| 03/31/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. ROOF PLAN ON A601 STILL INCOMPLETE. METAL GUTTERS INDICATED ON PLAN NOT SHOWN IN BUILDING SECTIONS/ELEVATIONS. ON EXISTING ROOF, NOTE INDICATES EXISTING SCUPPERS TO BE REPLACED BY ROOF AND OVERFLOW DRAINS. INDICATE THESE ON PLAN, AND DETAIL. 2. EXTERIOR BUILDING ELEVATIONS ON A301 STILL INCOMPLETE. SHOW ROOF DRAIN ELEMENTS. 3. DETAIL E-11/A501 IS STILL NOT CLEAR. BUILDING SECTION REFERENCE AND BUILDING PLAN REFERENCES ARE NOT CLEAR FOR THE SECTION SHOWN. 4. ALL TEXT ON DOCUMENTS SHALL BE 1/8" IN HEIGHT. 5. COORDINATE LIGHT POLE BASE DETAIL ON AS102/E101/STRUCTURAL CALCULATIONS. |
| 04/01/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Edmund Marquez - Suzuki Dealership Expansion T07CM04510 Building Plan (2nd Review) TRANSMITTAL DATE: April 03, 2008 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the building plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next building plan submittal. 3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C:\planning\grading\t07cm04510.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 04/15/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Provide location and sizing information for the gutters and downspouts. Reference: Section 1106.0, UPC 2006. |
| 04/16/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 04/23/2008 | JASON GREEN | ENGINEERING | REVIEW | Denied | Building plan can not be approved prior to site plan approval. |