Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM04464
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/26/2008 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | February 21, 2008 City of Tucson Development Services P.O. Box 27210 Tucson, AZ 85726 RE: Lakeside Park Comfort Station ADA – 2ND REVIEW CITY OF TUCSON LOG NO. T07CM04464 WILLDAN PROJECT NO. 13881-7084 The second review for the above project has been completed. This letter contains comments, which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter third review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2006 IBC, 1997 UAC, 2006 IMC, 2006 IECC, 2006 IFC, 2005 NEC, and the 2006 UPC. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Roger Brooks. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms N/A GENERAL COMMENTS: Sheet G0.1 New Comment: Please update the reference codes tot hose adopted by the City of Tucson. ARCHITECTURAL COMMENTS: New Comment: Regarding the note on accessibility: Please place the information in Note #2 of letter dated 1/16/08 on the cover sheet of the plans. PLUMBING COMMENTS: Sheet P1.1 New Comment: Please provide a potable water distribution isometric and show the locations of required water hammer arresters and trap primers. Reference Section 103.2.3 2006 UPC. New Comment: Please provide Trap Primers for the floor drains reference Section 1007.0 2006 UPC. New Comment: Please provide water pressure calculations for the potable water distribution as per City of Tucson submittal requirements. ACCESSIBILITY COMMENTS: Sheet AD1.1 New Comment: Please clarify General Note #5 regarding the demolition of the column. Reviewer was unable to identify the applicability of the note. Sincerely, WILLDAN Roger A. Brooks, C.B.O., V.P. Division Manager RAB/cc |
| 02/26/2008 | WILLDAN | ADA | REVIEW | Denied |