Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM04439
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Activity: T07CM04439 Date: 1/04/07 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. I. GENERAL REQUIREMENTS: " Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. " As of June 13, 2007 the City of Tucson has adopted the 2006 IRC and the 2006 UPC with local amendments. The plans should reference these codes, or appeal to the Building Official for 2003-design approval. " Verify scale callouts on all pages. II. FOUNDATION PLANS: " Provide foundation plan for porch enclosure. Note: All exterior framed walls require continuous concrete footings min. 12"wide x 12" below grade with treated sill plates and anchor bolts per R319.1 & R403.1.6 (including carport and porch enclosures). " Specify size and locations of concrete removal and replacement to facilitate new sanitary drainage line installation. " III. STRUCTURAL PLANS: " Provide a roof framing plan and show how the new wall framing relates to the existing structural design, R801.2. IV. SECTIONS - DETAILS: " Provide cross-section details for proposed porch enclosure. " Specify wall and ceiling covering. Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. V. PLUMBING PLAN: " Include laundry facilities on plumbing schematics. " Correct plumbing fixture symbol references and notes to accurately depict installation, R106.1.1. VI. MECHANICAL PLAN: " Provide a mechanical equipment specification list, M1302.1. " Show dryer vent size and location for venting to exterior (max 25' w/bend reductions), M1502.2, M1502.6. VII. ELECTRICAL PLAN: " Receptacles mounted below the countertop in accordance with this exception shall not be located where the countertop extends more than 6 inches beyond its support base, E3801.4.5. " Lights installed over a shower or bathtub must be approved for use in wet area, E3903.8. " Include sub-panel feeds for panels 'C' and 'D' in load calculations for panel 'B' and size accordingly, E3502.2. VIII. INTERNATIONAL ENERGY CONSERVATION CODE: " Specify the "R" value of the insulation to be installed in porch enclosure. The simplified prescribed energy values for ceilings R=30, and walls R=13, N1102.1. If you have any questions please contact: Clayton Trevillyan (520) 837-4913 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/09/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/09/2008 | SHANAE POWELL | REJECT SHELF | Completed |