Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T07CM04426
Parcel: 11201057B

Address:
2565 E PRINCE RD

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T07CM04426
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/29/2008 HENRY DURAZO BUILDING-RESIDENTIAL REVIEW Denied 1.Enclosed structure converted to living area has, a.substandard emergency exit window from bed room
b clean outs required at clothes washer & outside bath room
c.roof rafters are over spaned, 2x8's at 24" o.c. will span 14'0" max.
2. Bath stairs & deck addition 2nd floor,
a.specify guard &hand rail hieghts
b. show all required outlets in existing bed room

Final Status

Task End Date Reviewer's Name Type of Review Description
03/03/2008 CINDY AGUILAR OUT TO CUSTOMER Completed