Permit Number: T07CM04415
Parcel: 122184340

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T07CM04415
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/17/2008 ANDREW CONNOR LANDSCAPE REVIEW Approved
03/25/2008 HEATHER THRALL ZONING REVIEW Denied TO: Development Services Department, Plans Coordination Office
FROM: Heather Thrall, Senior Planner

PROJECT: T07CM04415, 3501 E. Speedway
New Office Complex
Commercial Site Plan, 2nd Review

TRANSMITTAL DATE: March 25, 2008

COMMENTS: Please resubmit revision with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed - OR email me for a counter appointment.

1. Per DS 2-02.2.1.8, regarding the parking:
A) (Per last review) please LIST the SQUARE FOOTAGE of EACH FLOOR of the building IN THE PARKING CALCULATIONS (I crunched numbers from notes on site plan and verified sufficient amount of parking - just list it in parking calc please.)
B) Two extra parking spaces are provided, correct the parking calc to list 168 required, 170 provided, based upon the building square footage notes and parking ratios required for each floor.
C) (Per this review) for microfilming, please enlarge the note that handicapped parking sign is to have a $518.00 fine for illegal parking - need 12 point type minimum.

2. Per DS 2-02.2.1.12, regarding pedestrian and handicapped access;
A) Per DS 2-08.4.1A & F, the positions of both crosswalks to the building- coming from Palo Verde and Speedway - need to be realigned to ensure no parking spaces are aligned for vehicles to back over the crosswalks.
B) declare the width of all sidewalks - adjacent to PAALs they need to be 5' wide

3. Per DS 2-02.2.1.20, I see the easements depicted on sheet 2 with their recordation notes awaiting abandonment, thank you. When the easements are abandoned, please note the docket and page of abandonment

4. Please note that further review comments may be forthcoming, depending upon the responses provided. I can be reached at Heather.Thrall@tucsonaz.gov or at 837-4951.

HCT C:\planning\site\DSD\T07CM04415 3501 E speedway 2.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
03/26/2008 HEATHER THRALL ZONING HC SITE REVIEW Denied Please see zoning review comments.
03/28/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Comment not addressed. Section R4-30-304 D of the Arizona Administrative Code states that a registrant shall sign, date, and seal professional documents that are to be submitted to any regulatory or review body.
2. Comment not addressed. Provide the rim elevation of the next upstream sanitary manhole and the first floor elevation. Determine the need for a backwater valve per Section 710.1, UPC 2006, as amended by the City of Tucson
04/28/2008 PAUL MACHADO ENGINEERING REVIEW Denied To: Louis Catallini DATE: April 28, 2008
Baker and Associates Engineering, Inc.
3561 E. Sunrise Drive, Ste. 225
Tucson, Arizona 85718

SUBJECT: Monte V Corp. Ctr., 3501 E. Speedway Blvd.
Site plan T07CM04415 (Second Review)
T14S, R14E, Section 04

RESUBMITTAL REQUIRED: Site Plan and Drainage Report.

The Site Plan (SP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. The future curb location for a 120' R/W is 9' from the R/W line. The fut. SVT must be shown on the plans. SVT's shall be shown at the NE corner of the intersection of Speedway Blvd. and Palo Verde Blvd. Per previous comment.
3. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the SP.
4. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. Per previous comment.
5. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. The detail 7/2 does not match the plan view. Also provide an adequate number of dimensions in order to build and inspect the refuse enclosure. Call out the dumpster as a City of Tucson Development Standard detail (modified). Show the 5" thick conc. approach apron for the refuse container. Per previous comment.
6. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice. Per previous comment.
7. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Per previous comment.

Drainage Report:
1. Engineering has accepted the DR for site plan purposes.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:\ 3501 E. Speedway Blvd. site 2

Final Status

Task End Date Reviewer's Name Type of Review Description
05/01/2008 DELMA ROBEY OUT TO CUSTOMER Completed
05/01/2008 SHANAE POWELL REJECT SHELF Completed