Permit Number: T07CM04400
Parcel: 11918036A

Address:
3610 S 12TH AV

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T07CM04400
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/11/2008 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: St. Johns Neighborhood Park
T07CM04400
Site Plan (3rd Review)

TRANSMITTAL DATE: June 11, 2008

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the area of the park expansion only.

2. Zoning acknowledges the provided copy of the Lease Agreement Second Amendment, unsigned. The lease agreement area is still not clearly indicated on the plan. There is a line that appears like a property line which may have been the original lease agreement. This line needs to be modified to include the parking.

3. D.S. 2-02.2.1.A.8 On the angled handicapped vehicle parking space detail provide the "A" Parking Angle, "C" Space Depth, and "E" Curb Length, see attached LUC 3.3.7.2 Motor Vehicle Parking Space Dimensions. Ensure that these dimension meet the minimum requirements of LUC Table 3.3.7.I, see attached.

4. This comment was not fully addressed. Provide a detail that includes the materials for lighting, fully dimensioned layout. D.S. 2-02.2.1.A.9 Show the required off-street bicycle parking location on the plan. Provide a detail that includes the materials for lighting, paving, and security; fully dimensioned layout; location; specific type of rack and the number of bicycles it supports; and the location and type of directional signage if required.

5. This comment was not addressed. Please clarify what "NEIGHBORHOOD RECREATION "6" is for. The correct development designator is "12" subject to Sec. 3.5.13.2 and Sec. 3.5.13.3.D.S. 2-02.2.1.A.31 Provide the existing and proposed use on the plan. The development designator shown on the plan is incorrect. Per LUC Sec. 2.3.4.2.E.1 and Sec. 2.3.5.2.E.1 the development designator for Neighborhood Recreation is "12" subject to Sec. 3.5.13.2 and Sec. 3.5.13.3.

6. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t07cm04400-3rd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
06/13/2008 RBROWN1 ADA REVIEW Approved
06/24/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
06/25/2008 CINDY AGUILAR OUT TO CUSTOMER Completed
06/25/2008 SUE REEVES REJECT SHELF Completed