Permit Number: T07CM04363
Parcel: 12112399F

Review Status: Completed

Review Details: SITE

Permit Number - T07CM04363
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/14/2007 MARTIN BROWN FIRE REVIEW Denied Please indicate location of existing fire hydrants, with dimensions to property lines. Per C.O.T. amendments to the 2006 IFC (section 508), fire sprinklers or an additional on site fire hydrant may be requirede.
11/15/2007 TSTEVEN1 ADA REVIEW Passed
11/20/2007 TERRY STEVENS ZONING REVIEW Denied TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: T07CM04363
1634 N. Beverly Ave.
Site Plan

TRANSMITTAL: 11/20/07

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. DS 2-02.2.1.1 North arrow on each sheet does not appear to be correct. Revise.

2. Enlarge the lettering inside of the title block to a minimum font size of 12 pt.

3. DS 2-02.2.1.3 Provide the project address on each sheet of the submittal.

4. DS 2-02.2.1.6 Provide dimensions for the footprint of all structures on the site plan.

It appears per aerial photos that there is a covered area connecting the two structures. Provide on site plan clearly indicating if this area is a porch or useable floor space.

5. DS 2-02.2.1.7 Note #5 regarding required setbacks is incorrect. Revise as follows:
North setback-- required 0' provided 8.8'
East setback-- required 0' provided 35.1'
South setback-- required 1 ½ X height (16')=22' provided 24.1'
West setback-- required 20' or 1 ½ X height(16)=22' provided 30'

6. DS 2-02.2.1.8 Provide on detail 2 of 4 the correct verbiage for the handicap parking sign. A copy of the correct sign can be obtained at the front counter at DSD.

Per City of Tucson standards the minimum height from grade to the bottom of the main sign for the handicap parking sign is seven (7) feet. Revise detail 2 of 4.

7. DS 2-02.2.1.9 Please provide a plan view detail of the proposed class 2 bicycle parking spaces. Single rack spaces placed in a row will allow a minimum of seventy -two (72) inch length per bicycle parking space and a minimum of thirty (30) inches between outer spaces of racks. A five (5) foot wide access aisle measured from the front or rear of the seventy-two (72) inch long parking space will be provided beside each row. Lighting will be provided such that all facilities are thoroughly illuminated and visible from adjacent sidewalks, parking lots, or buildings, during working hours. The surface of the facility can be surfaced the same as for motor vehicle parking or with a minimum of one (1) inch thickness of one-fourth (1/4) inch aggregate material.
DS 2-09.5.1, DS2-09.5.2, DS 2-09.5.4, & DS 2-09.6.2

The ribbon type bicycle rack indicated on detail 11 of 4 is not an acceptable type of class 2 bicycle rack. See DS 2-09 figure 4. For acceptable types of racks see DS 2-09 figures 2 and 3. Provide a detail for the revised class 2 bicycle rack.

8. DS 2-02.2.1.10 Provide existing sight visibility triangles. See engineering comments.

9. DS 2-02.2.1.11 Dimension widths of PAALs including access PAAL from street.

Provide dimensions for the backup spur, width, 3' radius and 3' clearance behind backup spur as per DS 3-05 Figure 2.

Per DS 3-05.2.3.C.1 A vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from extending beyond the property lines; damaging adjacent landscaping, walls, or buildings; or overhanging adjacent sidewalk areas or unpaved areas on or off site and to prevent vehicles from driving onto unimproved portions of the site. This comment applies to areas around the loading zone and the trash enclosure.

Remove the items which are indicated as being demolished from the site plan. These items can be or are indicated on sheet 3 of 4.

10. DS 2-02..2.1.12 Per DS 2-08.3.1 Within all development, a continuous pedestrian
circulation path is required. This path must connect all public access areas of the
development and the pedestrian circulation path located in any adjacent streets. Sidewalk missing to Beverly Ave and also must provide pedestrian circulation path to the trash enclosure.

Clearly indicate the width of all sidewalks. Minimum width is four (4) feet.

Provide a four (4) foot wide sidewalk at the west side of the south building between the building and the backup spur.

Truncated domes are required on the sidewalk the full width of the handicap access aisle. Minimum depth of 24" is required. Indicate on the site plan and detail 8 of 4.

11. DS 2-02.2.1.13 If applicable, provide location, type, size and height ofexisting and proposed signage, including billboards.

12. DS2-02.2.1.25 If applicable, provide existing and proposed lighting layout and type.

13. Depending upon changes to this plan and responses to the above comments, additional comments may be forth coming.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

TLS C:\zoning\siteplan\DSC\T07CM04363.doc
11/20/2007 TERRY STEVENS ZONING HC SITE REVIEW Denied see zoning comments.
12/02/2007 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. Submit a separate landscape plan per DS 2-07.0. to verify that entire site meets current minimum requirements.

2. Submit an irrigation plan showing irrigation specification design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

3. Dimension the minimum width and label the square footage measured from the inside of tree planters in the vehicle use area. An unpaved area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree. Revise planter dimensions as required.
LUC 3.7.2.3.A.1.c, DS 2-07.2.2.A.2.e

4. Revise north arrows to be correct on all sheets.

5. Additional comments may apply upon submittal of a landscape plan.
12/03/2007 PETER MCLAUGHLIN NPPO REVIEW Denied Submit an Application for Exception to the Native Plant Preservation Ordinance. Include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property. Photographs of the site are necessary for NPPO approval per DS 2-15.2.0.C
12/19/2007 JASON GREEN ENGINEERING REVIEW Denied DATE: December 19, 2007
SUBJECT: 1634 N Beverly Avenue Site Plan- Engineering Review
TO: Kristin Diaz
LOCATION: T14S R14E Sec02 Ward 6
REVIEWERS: Jason Green, CFM
ACTIVITY: T07CM04363 (Site Plan)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the site plan (T07CM04539) and Drainage Statement (Arizona Engineering Designs, 07NOV07) for the above referenced property. Engineering Division does not recommend approval of the site plan application at this time. The following items need to be addressed:


SITE PLAN COMMENTS:

1) The correct site plan number (T07CM04363) can be added to the lower right hand corner of the plan sheets where indicated by "DPR-XXXX."

2) DS Sec.2-02.2.1.A.1: Revise the north arrow on all Sheets to point north, not magnetic/true north.

3) DS Sec.2-02.2.1.A.2: Revise the Title Block on all Sheet to increase the type font to the equivalent of 12 point to assure that the lettering is legible when reproduced or when photographically reduced for record keeping purposes. Specifically for the legal description.

4) DS Sec.2-02.2.1.A.3: Provide the administrative address for the subject property on the site plan.

5) DS Sec.2-02.2.1.A.8: Revise the site plan and detail 1/4 to include the 6-inch extruded curbing around the southern portion of the proposed vehicular use area. Curbing is required to prevent encroachment onto the adjacent property and landscape area.

6) DS Sec.2-02.2.1.A.8: Revise the site plan to provide dimensions for the proposed back-up spurs with a minimum of 3 feet in depth, a 3-foot radius, and a 3 foot separation between curb and any proposed walls or unsurfaced areas. Refer to DS Sec.3-05.2.2.D for clarification. Verify the minimum 4-foot width requirement for the pedestrian circulation along with the back-up spur dimensions.

7) DS Sec.2-02.2.1.A.8: Revise the site plan to dimension, or provide a detail, for all planting areas that are within the vehicular use area. Refer to DS Sec.2-06.3.3.C and Figure 3 under DS Sec.3-05 for square footage and minimum width/radii requirements.

8) DS Sec.2-02.2.1.A.8: Verify the minimum required 24-foot dimensions for the 2-way PAAL shown on the site plan.

9) D.S. 2-02.2.1.A.10: Revise the site plan to clearly show the sight visibility triangles that are required for the PAAL intersection with the local road. Label and dimension the sight visibility triangles in plan view to verify that no obstruction are within these areas. Refer to DS Sec.3-01.5.1 for triangle criteria.

10) DS Sec.2-02.2.1.A.11: Label and dimension the minimum PAAL entrance widths for the vehicular use area shown on the site plan. Refer to the Transportation Access Management Guidelines for minimum curb cut and drive way entrance requirements at public roadways for street development standards.

11) DS Sec.2-02.2.1.A.11: Depict and label the 18-feet radii concrete curbs returns per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the proposed driveway entrances. The curbs should be constructed at the edge of pavement, which must also be depicted on the site plan. Curb returns must be constructed entirely within the subject parcel. Refer to DS Sec.3-01.3.2.C and the Transportation Access Management Guidelines for street development standards. For standard driveway entrances review and approval from Tucson Department of Transportation, Jose Ortiz, P.E., is required.

12) DS Sec2-02.2.1.A.12: Revise the site plan to provide the required 5-foot wide sidewalk along the street frontage of Beverly Avenue. Refer to DS Sec.3-01 for all curb and sidewalk requirements. If an existing sidewalk is already constructed along the frontage of Beverly Avenue provide photo documentation showing that the existing sidewalk is in good condition. If the sidewalk is missing in spots or is cracked and buckled a new 5-foot sidewalk will be required. A DSMR will be required for modifying the development standards to allow a sidewalk that does not meet the minimum 5-foot width requirements. The DSMR must be approved prior to site plan approval. All exhibits and discussion must reflect any changes made by the approved DSMR. Provide a General Note to list the DSMR number, the Development Standard being modified along with the date of DSMR approval.

13) DS Sec.2-02.2.1.A.12: Revise the site plan to label and dimension all onsite pedestrian circulation areas. Pedestrian circulation (westside of each building) must provide a clear 4-foot minimum width unless adjacent to a PAAL which would require a 5-foot width.

14) DS Sec.2-02.2.1.A.12: Revise the site plan to show the location of all scuppers existing/proposed under the sidewalk for roof drainage. Provide separate details for the scuppers showing the standard detail number for public improvements required meeting these requirements in order to convey the 10-year flow under the pedestrian circulation.

15) DS Sec.2-02.2.1.A.12: Revise the site plan to show the required pedestrian circulation path that is required to connect the existing building and vehicular use area to the required sidewalk along Beverly Avenue. Label and dimension all pedestrian circulation paths.

16) DS Sec.2-02.2.1.A.12: Revise the site plan to provide a handicap access ramp for the handicap parking space. Revise the plan to show that all existing and proposed handicap access ramps meet the design requirements per ANSI Standards A117.1-2003 Section 406.13. Provide details or keynotes that label truncated domes at all transitions from pedestrian circulation to vehicular circulation.

17) DS Sec.2-02.2.1.A.12: Verify that the landing for the required handicap ramp is physically separated from the vehicular use area. Verify that the required ADA access ramp provides for the required 5-foot landing at the top of the ramp to meet ADA compliance.

18) DS Sec.2-02.2.1.A.12: Revise the site plan to provide the required pedestrian circulation path from the proposed buildings to the refuse enclosure.

19) DS Sec.2-02.2.1.A.16: Revise the site plan so that the stormwater discharge from the proposed vehicular use area and the off-site flow drains into the proposed planting areas and the 10-foot front landscape border/water harvesting area to help reduce onsite flows from leaving the site. Provide a curb cut with dimensions to show that stormwater drains into the landscape area to minimize offsite impacts due to the developed discharge values.

20) DS Sec2-02.2.1.A.16: Provide flow arrows on the site plan to identify drainage patterns for the roof drainage to verify downspout and scupper locations.

21) DS Sec2-02.2.1.A.17: Provide the estimated cut and fill quantities on the revised site plan for grading plan purposes.

22) DS Sec.2-01.2.1.A.21: Provide dimensions from the street monument lines to the existing and/or proposed curb, sidewalk, driveway and any utility lines.

23) DS Sec.2-02.2.1.A.32: Revise the site plan and detail 7/4 to show that the refuse enclosure meets the minimum requirements of DS Sec.6-01. The enclosure must have a minimum inside clear dimension of 10 feet by 10 feet between bollards that are required between the container and the enclosure's rear and sidewall. Refer to Figure 3 (attached to the hard copy of this letter) and DS Sec.6-01.4.2 for specifications and requirements on access, placement of containers, bin enclosure and construction.

24) DS Sec.2-02.2.1.A.32: Show maneuverability (label and dimension turning radii in plan view) for refuse vehicles in plan view.

25) Review and approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Refer to the following links for TDOT Forms and applications:

a) http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/applications.html /

b) http://www.dot.ci.tucson.az.us/engineering/pia.php

c) Or contact Thad Harveston at 837-6592 for all additional questions regarding r-o-w.

26) Be advised that further comments may be forth coming on resubmittal of the site plan.


GENERAL COMMENTS:

Please provide a revised site plan that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Enclose "redlines" with the resubmittal package.

Further comments may be generated upon resubmittal of the site plan review.

If you have any questions, or to schedule an appointment, I can be reached at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services

Final Status

Task End Date Reviewer's Name Type of Review Description
01/09/2008 DELMA ROBEY OUT TO CUSTOMER Completed
01/09/2008 SHANAE POWELL REJECT SHELF Completed