Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T07CM04220
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/23/2007 | CARL SCHULTZ | FIRE | REVIEW | Approved | |
| 11/26/2007 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Approved | |
| 11/26/2007 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: 1005 & 1015 East Fort Lowell Road T07CM04220 Site Plan (2nd Review) TRANSMITTAL DATE: November 26, 2007 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the entire site. 2. It appears that a lot split is proposed for this parcel. The lot split must be completed prior to approval of the site plan. Also some type of access easement or access agreement, vehicle and pedestrian, will need to be recorded prior to approval of the lot split. This easement/agreement needs to include the pedestrian circulation, sidewalk that runs along the west property line and the pedestrian circulation and the southern portion of the parking area access lane (PAAL) located between the proposed buildings. 3. This comment was not fully addressed, provide a detail that includes; materials for lighting, paving, and security; fully dimensioned layout; location; specific type of rack and the number of bicycles it supports; and the location and type of directional signage if required. Signage is required as the proposed location is not clearly visible, see D.S. 2-09.4.0. D.S. 2-02.2.1.A.9 Per LUC Sec. 3.3.4, RESIDENTIAL USE GROUP, for any multifamily project of four (4) or more units, bicycle parking is required at the following ratio: eight (8) percent of the provided number of vehicle parking spaces, fifty (50) percent Class 1 & fifty (50) percent Class 2. Per LUC Sec. 3.3.3.5 If the calculated number of bicycle parking spaces is less than two (2), the minimum number of required spaces is two (2). Per LUC Sec. 3.3.7.8.A Any use providing less than fifty (50) motor vehicle parking spaces may substitute Class 2 for Class 1 spaces. This said, show the location, on the plan, of the two (2) Class 2 bicycle parking spaces. Also provide a detail that includes; materials for lighting, paving, and security; fully dimensioned layout; location; specific type of rack and the number of bicycles it supports; and the location and type of directional signage if required. 4. Zoning acknowledges that a 24' access easement is proposed. The access easement must include pedestrian access. D.S. 2-02.2.1.A.20 If applicable show all easements of record graphically on the plan together with recording docket and page reference. 5. Additional comments may be forth coming depending on how each comment has been addressed. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t07cm04220-2nd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 11/27/2007 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 11/27/2007 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 12/03/2007 | DROBEY1 | PLUMBING-COMMERCIAL | REVIEW | Needs Review | |
| 12/03/2007 | LOREN MAKUS | ENGINEERING | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/03/2007 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 12/03/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 12/03/2007 | DELMA ROBEY | REJECT SHELF | Completed |