Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T07CM04213
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/12/2008 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 06/12/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 06/12/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Desert Dog Automotive - Building Addition T07CM04213 Site Plan (3rd Review) TRANSMITTAL DATE: June 12, 2008 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the entire site due to an expansion greater than twenty-five (25) percent. This plan has been reviewed as a COMMERCIAL SERVICES USE GROUP, Automotive - Service and Repair, Major. 2. D.S. 2-02.2.1.A.12 Per D.S. 3-05.2.2.D A minimum distance of three (3) feet will be provided between the back of spur and any wall, screen, or other obstruction over six (6) inches in height. This said the 2'-6" dimension to the fence at the backup spur shown at the west end of the parking area does not meet this requirement. 3. D.S. 2-02.2.1.A.12 The required pedestrian circulation/accessible route shown between the vehicle parking spaces, near the storage containers, is require to be a four (4) foot sidewalk physically separated from the vehicle parking spaces. 4. Ensure that all changes to the site plan are reflected on the landscape plan. 5. Additional comments may be forth coming depending on how each comment has been addressed. 6. Zoning is willing to provide an over-the-counter review once all above comments have been addressed. Please call or email for an appointment. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t07cm04213-3rd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 06/19/2008 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed | |
| 06/19/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. |
| 06/24/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 07/01/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: July 1, 2008 SUBJECT: Garage Addition - Full Compliance TO: Antonio Romano LOCATION: 770 W Grant Road, T14S, R14E, Section 18, Ward 5 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T07CM04213 (Third Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. Be sure to include response letter with next submittal. 2. The most recent aerial photo of the building does not match what is depicted on the site plan. Please modify site plan to represent actual footprint of building and/or clarify. Explain what is going to be done with the storage structures that are on site. 3. Complied 4. Complied 5. Per D.S. 2-02.2.1.4: Location map should provide the following information: a. Complied b. Complied c. Section, township, range 6. Provide lot bearings per D.S. 2-02.2.1.5 7. Complied 8. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. Verify that sight visibility triangles have been accurately depicted on site plan. 9. Add dimensions for parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 10. Provide Traffic engineering signature on site plan - unable to locate signature. 11. Complied 12. Provide Traffic engineering signature on site plan - unable to locate signature.. 13. Complied 14. Complied 15. Complied 16. Complied 17. Complied 18. Provide drainage patterns for southern portion of parcel in addition to the drainage arrows already provided in the northern portion of parcel per D.S. 2-02.2.1.16. 19. Complied 20. Complied 21. Complied 22. Complied 23. Complied 24. DS Sec.2-02.2.1.A.19: Label the 9-foot future sidewalk and curb area on the site plan to verify that all improvements are located outside of the future ROW. Clarify bold dashed line on site plan. 25. Complied 26. Complied 27. Complied. 28. Complied 29. Complied 30. Complied 31. Complied 32. Complied 33. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 34. Complied 35. Complied 36. Provide phone number for owner. 37. Complied 38. Complied 39. Complied 40. Complied 41. Provide a dimension for the PAAL that is between the sidewalk, located on the south side of the building and the south property line. It does not appear that the PAAL meets the minimum 24' foot width for a two way PAAL. 42. Add back up dimensions for back up spurs. 43. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/17/2008 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 07/17/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 07/17/2008 | DELMA ROBEY | REJECT SHELF | Completed |