Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM04213
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/12/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Desert Dog Automotive - Building Addition T07CM04213 Building Plan (3rd Review) TRANSMITTAL DATE: June 12, 2008 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the building plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next building plan submittal. 3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C:\planning\grading\t07cm04213.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 06/12/2008 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 06/12/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 06/24/2008 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 06/30/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: July 1, 2008 SUBJECT: Garage Addition - Full Compliance TO: Antonio Romano LOCATION: 770 W Grant Road, T14S, R14E, Section 18, Ward 5 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T07CM04213 (Third Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. Be sure to include response letter with next submittal. 2. The most recent aerial photo of the building does not match what is depicted on the site plan. Please modify site plan to represent actual footprint of building and/or clarify. Explain what is going to be done with the storage structures that are on site. 3. Complied 4. Complied 5. Per D.S. 2-02.2.1.4: Location map should provide the following information: a. Complied b. Complied c. Section, township, range 6. Provide lot bearings per D.S. 2-02.2.1.5 7. Complied 8. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. Verify that sight visibility triangles have been accurately depicted on site plan. 9. Add dimensions for parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 10. Provide Traffic engineering signature on site plan - unable to locate signature. 11. Complied 12. Provide Traffic engineering signature on site plan - unable to locate signature.. 13. Complied 14. Complied 15. Complied 16. Complied 17. Complied 18. Provide drainage patterns for southern portion of parcel in addition to the drainage arrows already provided in the northern portion of parcel per D.S. 2-02.2.1.16. 19. Complied 20. Complied 21. Complied 22. Complied 23. Complied 24. DS Sec.2-02.2.1.A.19: Label the 9-foot future sidewalk and curb area on the site plan to verify that all improvements are located outside of the future ROW. Clarify bold dashed line on site plan. 25. Complied 26. Complied 27. Complied. 28. Complied 29. Complied 30. Complied 31. Complied 32. Complied 33. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 34. Complied 35. Complied 36. Provide phone number for owner. 37. Complied 38. Complied 39. Complied 40. Complied 41. Provide a dimension for the PAAL that is between the sidewalk, located on the south side of the building and the south property line. It does not appear that the PAAL meets the minimum 24' foot width for a two way PAAL. 42. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 07/03/2008 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 520.837.4907 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. 1. Either specify that all conduit be run overhead, or specify the wiring method per NEC 511.4. 2. Either specify that all conduit be run overhead, or specify the required seals per NEC 511.9 and 501.15. 3. Please specify that the receptacles be GFCI protected. Reference NEC 511.12. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/11/2008 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |