Permit Number: T07CM04148
Parcel: 11104219B

Address:
3237 N RICHEY BL

Review Status: Completed

Review Details: SITE

Permit Number - T07CM04148
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/29/2007 DAVE MANN FIRE REVIEW Approved
11/01/2007 STEVE SHIELDS ZONING HC SITE REVIEW Denied See Zoning Comments
11/02/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Horticulture Unlimited Inc.
T07CM04148
Site Plan (1st Review)

TRANSMITTAL DATE: November 1, 2007

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the area of expansion only.

2. It appears that this project is comprised of two (2) different parcels. There are two (2) options in regards to utilizing the two (2) parcels as one site. Prior to approval of the site plan provide; 1) A Pima County Tax Parcel Combo and a recorded covenant regarding development and use of real property, or 2) Provide a site plan for each parcel that shows how the parcels can stand alone, if sold separately, and meet the requirements of the LUC if sold separately along with a recorded covenant regarding development and use of real property.

3. All lettering and dimension shall be the equivalent of twelve (0.12") point or greater in size to facilitate reproduction and photographically reduced (microfilm) for record keeping. There are text strings and lot line distances that do not meet this requirement.

4. A demo permit is required for removal of the existing carport and storage building.

5. D.S. 2-02.2.1.A.2 Provide a property description (legal description) on the plan.

6. D.S. 2-02.2.1.A.4 Provide a location map that meets the minimum requirements of D.S. 2-05.2.1.D, identify conditions within the square mile area, such as watercourses, section, township and range, section corners, and scale.

7. D.S. 2-02.2.1.A.5 Provide lot line bearings on the plan.

8. D.S. 2-02.2.1.A.8 Based on the 420 sq. ft. expansion two (2) additional vehicle parking spaces are required. Show the location for the additional parking spaces on the plan. Based on the aerial photos an expansion of parking area (paved area) will be required to accommodate the two (2) required parking spaces, provide an expansion calculation for this expansion. Provide a typical vehicle parking space detail for a standard space on the plan.

9. D.S. 2-02.2.1.A.9 Based on the aerial photos it does not appear that the bicycle parking shown on the plan is existing. If this is the case provide off-street bicycle parking detail; including materials for lighting, paving, and security; fully dimensioned layout; location; specific type of rack and the number of bicycles it supports; and the location and type of directional signage if required. Ensure that the play layout meets the current requirements of D.S. 2-09.

10. D.S. 2-02.2.1.A.10 Show the existing sight visibility triangles (SVT's) on the plan.

11. D.S. 2-02.2.1.A.12 Based on the provided plan and the aerial photo there is a proposed change to the accessible route from the existing accessible vehicle parking space to the building. It appears that the proposed crosswalk does not align with the existing accessible ramp, please clarify.

12. D.S. 2-02.2.1.A.28 Provide the zoning for the parcel to the west.

13. D.S. 2-02.2.2.A.3 The allowable floor area ratio (FAR) is not correct. Per LUC Sec. 3.2.3.2.B Development Designator "30" the allowable FAR is 0.75. Also remove the reference to Lot Coverage as it is not applicable to this project.

14. D.S. 2-02.2.2.A.4 The provided parking calculation is not correct. The proposed expansion of 420 sq. ft. (420/250 = 1.68) or 2 additional vehicle parking spaces required. Revise the vehicle parking space calculation.

15. The allowable building height shown on the plan in not correct. Per LUC Sec. 3.2.3.2.B Development Designator "30" the maximum building height allowed is 40'

16. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t07cm04148.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
11/02/2007 SREEVES1 ADA REVIEW Passed not a COT project
11/07/2007 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the plans to document copmpliance with the landscape and screening regulations in effect at the time the existing development received zoning approval per LUC 3.7.1.2.B.1.A. Show the required street landscape border for 3237 N Richey (parking lot and office building).

2) Document compliance with the vehicular use area surfacing requirements of LUC 3.3.7.3. Define the limits of the vehicular use area with a barrier per DS 3-05.2.3.c.1 and show the surfacing therein.

3) Revise the plan to clarify that the screening requirements are met on the north side of the roll gate also.
LUC Table 3.7.2-I
11/08/2007 JOE LINVILLE NPPO REVIEW Approved Exception per 2005 aerial photo.
11/14/2007 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: November 14, 2007
SUBJECT: Metal Building
TO: MPE
LOCATION: 3237 N Richey Blvd, T14S, R14E, Section 18, Ward 5
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T07CM04148 (First Review)


RESUBMITTAL REQUIRED: Site Plan

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. The most recent aerial photo of the building does not match what is depicted on the site plan. It appears that proposed metal building appears to be located on property address 3249 N Richey Blvd. Clarify why permit listed under adjacent property.
3. Verify that all lettering and dimensions are equivalent to twelve (0.12) point or greater in size. The purpose of this requirement is to assure that all lettering is legible when reproduced or when photographically reduced (microfilmed) for record keeping purposes.
4. Please provide property description per D.S. 2-02.2.1.2.
5. Please provide property address per D.S. 2-02.2.1.3. Proposed metal building appears to be located on property address 3249 N Richey Blvd.
6. DS Sec.2-02.2.1.A.4: Revise the project location map on Sheet TS1. Project location map is to be drawn at a scale of 3" = 1 mile. Provide section, township and range, section corners and scale 3" = 1 mile).
7. Provide lot bearings per D.S. 2-02.2.1.5
8. Provide existing sight visibility triangles per D.S. 2-02.2.1.10.
9. Provide Drainage patterns and roof drainage arrows per D.S. 2-02.2.1.16.
10. Provide estimated cut & fill quantities per D.S. 2-02.2.1.17. It appears that cut and fill will not be occurring for the proposed patio. However, as part of the site submittal requirement estimated cut and fill quantities are required to be indicated on the plans so that it is clear to the inspector that no cut in fill is to be taking place. If not cut and fill is taking place indicate the quantity of zero (0) on the plan. Estimated cut and Fill: Cut = 0 and Fill = 0 will suffice.
11. Provide supporting documentation for right of way dimensions provided on site plan per D.S. 2-02.2.1.19.
12. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for Richey Blvd.
13. Verify that all easement of record have been graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20.
14. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
15. Provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Provide contour interval on plan.
16. Show Site plan activity number on each sheet in the lower right hand corner per D.S. 2-02.2.1.29.
17. Demolition permit required for removal of carport and storage building. Provide demolition activity number on each sheet in the lower right hand corner per D.S. 2-02.2.1.29.
18. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
19. All symbols on plans need to be indicated in legend. Indicate all symbols in legend.
20. Approval from zoning required in regards to separate addresses. See zoning comments for compliance.
21. Additional comments may be forthcoming.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax

Final Status

Task End Date Reviewer's Name Type of Review Description
01/04/2008 DELMA ROBEY OUT TO CUSTOMER Completed
01/04/2008 DELMA ROBEY REJECT SHELF Completed