Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM04134
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/22/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
| 10/22/2007 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 11/05/2007 | GERRY KOZIOL | WWM | REVIEW | Denied | needs 8th floor credit evaluation |
| 11/07/2007 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | GENERAL COMMENT: WHEN A CHANGE OF OCCUPANCY IS INITIATED, ALL BUILDING COMPONANTS MUST BE BROUGHT UP TO CODE COMPLIANCE: 1. TABLE 602 REQUIRES THAT BOTH EAST AND EAST EXTERIOR WALLS MUST HAVE A 2 HOUR FIRE RATING. 2. THE SHED COVERING THE REAR SLAB NEEDS TO BE CLARIFIED ON THESE DOCUMENTS. 3. NEED GRADING PLAN TO SHOW ACCESSIBILITY TO SITE AND TO BUILDING ENTRY 4. NEED HI LOW DRINKING FOUNTAIN AS PER ANSI117.2/602.5 STORAGE ROOM NOS. 107 AND 109 NEED TO BE TWO HOUR RATED, TABLE 508.2 5. SINK IN ROOM 105 MUST BE ACCESSIBILE |
| 11/07/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 11/07/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide water supply plans and isometrics. Reference Section 103.2.3, UPC 2006. 2. Provide the minimum plumbing facilities (i.e. a service sink) required by Table 2902.1 and Section 2902.2, IBC 2006, for mercantile occupancy. 3. Provide information to show how the outlet temperature of the hot water is to be limited to 110 degrees at the lavatory. Reference Section 413.1, UPC 2006 and Section 504.3, IECC 2006. http://www.ci.tucson.az.us/tucsonwater/clearwater?output=allTabular |
| 11/07/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide information on the sequence of operation for the restroom exhaust to show that recirculation of the air from the restroom will not occur. Reference Section 403.2.1, IMC 2006. 2. Section 403.3, IMC 2006, as amended by the City of Tucson allows the use of the ASHRAE 62-1-2004 ventilation calculation procedure provided that the default occupant densities and combined outdoor air rates are used. 3. Table 6-2, ASHRAE 62-1-2004 indicates that a Zone Air Distribution Effectiveness (Ez) value of 0.8 is required if the ceiling supply of warm air is 15 degrees Fahrenheit or more higher than the space temperature. |
| 11/19/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/21/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 11/21/2007 | DELMA ROBEY | REJECT SHELF | Completed |