Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM04123
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/20/2007 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Activity: T07CM04123 Date: 11/20/07 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. I. GENERAL REQUIREMENTS: · Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. II. FOUNDATION PLANS: § All exterior framed walls require continuous concrete footings min. 12"wide x 12" below grade with treated sill plates and anchor bolts per R319.1 & R403.1.6 (including carport enclosures). III. SECTIONS - DETAILS: § Eave vents require min. 1" clearance between ceiling insulation and roof sheathing, R806.3. Specify the type of insulation that will provide the prescriptive value of R-30 in the roof assembly and allow for the proposed eave venting. IV. PLUMBING PLAN: · As of June 13, 2007 the City of Tucson has adopted the 2006 UPC with amendments. The plans should reference these codes, or appeal to the Building Official for 2003 UPC-design approval. · Provide the size of the water meter and the diameter of the water service line to the house, UPC Table 6-6. Note: The Tucson Water policy adopted 3/2/07 limits the maximum demand for a 5/8" water meter (there are no ¾" meters for Tucson Water service) to 10GPM. V. ELECTRICAL PLAN: § Clarify which circuits will be arc-fault protected. § Provide a note or show locations of smoke detectors (every sleeping room and hallways leading to). When ceiling finish materials are not removed, existing bedrooms may be equipped with battery operated smoke detectors, R313. § Show the size and location of all cleanouts, UPC 707.4, Table 7-6. § Specify the diameter of all sanitary drain lines and the location of the sewer connection, UPC Table 7-5. VI. INTERNATIONAL ENERGY CONSERVATION CODE: § Specify the "R" value of the insulation, as well as the "U" factor and the solar heat gain coefficient of the windows and doors. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing is U=0.75, ceiling R=30 and walls R=13, N1102.1. If you have any questions please contact: Clayton Trevillyan (520) 837-4913 City of Tucson Residential Plan Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
11/23/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
11/23/2007 | DELMA ROBEY | REJECT SHELF | Completed |