Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM04111
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: January 4, 2007 SUBJECT: New Duplex TO: Donald Riley LOCATION: 1090 E Alvord Rd, T15S, R14E, Section 7, Ward 5 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T07CM04111 (Second Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Include a response letter to the comments along with the corrected copies of the Site Plan with next submittal. Note that if 3rd review consists of comments a minimum 2 hour review fee will be applied. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the Site Plan. 2. DS 2-02.2.1.4: Revise location map- Provide section, township and range; sections corners. Clean up map so that it is easier to read. Remove surrounding parcels. 3. Lot dimensions acknowledged - provide bearings and indicate basis of bearings per D.S. 2-02.2.1.5 4. Label all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6. Indicate height of buildings and clarify if existing building is being demolished. If so, demo plan and permit will be required. If demo permit has already been issued provide permit number. 5. Provide existing sight visibility triangle per D.S. 2-02.2.1.10. SVT acknowledged along Alvord Road - provide SVT along Jeanette Blvd. 6. DS Sec.2-02.2.1.A.11: Show all points of egress and ingress including locations and width of driveways. Revise the site plan to show that the minimum 20 ' distance from a curb line or a cross street at a street intersection has been met. In addition, show 12-foot separation that is required between adjacent driveways. Show and label the existing and proposed driveways and include driveways adjacent to the site and verify the 12-foot minimum width. Refer to Tucson Code (TC) Chapter 25-39 for curb cut and driveway requirements. 7. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for Alvord Road and Jeanette Blvd. Also indicate that road is public. 8. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. Verify that all easements have been identified on site plan along with required information. 9. For clarity label dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 10. D.S. Sec.2-02.2.1.16: Provide drainage patterns. 11. Complied. 12. D.S. Sec.2-02.2.1.23: Provide existing and proposed topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. 13. D.S. Sec.2-02.2.1.27: Verify that all fences, walls, or vegetation for screening and sight visibility are shown by type, material, height, location and spacing. 14. Complied 15. DS Sec.2-05.1.4.H.2: Review and approval from TDOT Permits and Codes for all proposed improvements including sidewalk within the public right of way will be required. A right-of-way use permit application will be required prior to construction. Contact Thad Harvison at 791-5100 for all right-of-way requirements and permit applications. 16. Complied. 17. Additional comments may be forthcoming based on verification, modification, and revisions. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 12/14/2007 | GERRY KOZIOL | WWM | REVIEW | Denied | needs credit evaluation, 8th floor |
| 12/24/2007 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Approved | |
| 12/27/2007 | DAVID RIVERA | ZONING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/09/2008 | THAUSER1 | OUT TO CUSTOMER | Completed |
| 01/08/2008 | SHANAE POWELL | REJECT SHELF | Completed |