Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM04110
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/19/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
11/05/2007 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. NEED SITE PLAN SHOWING ACCESSIBILITY PARKING AND ROUTES 2. CODE DATA NEEDS TO BE SHOWN ON SHEET A-001; I.E. BUILDING TYPE, OCCUPANCY, ZONEING, BLDG CLASSIFICATION AND ETC. 3. ARCHITECTURAL FLOOR PLANS NEED TO BE CORRECTED TO SHOW AND REFERENCE MODIFIED TOILET LAYOUT AND DETAILS ON A-601/2. 4. PROBLEMS WITH TOILET PLAN AND LAYOUT; VERTICLE BAR AT TOILET STALLS, ANSI 117.1/604.5.1, URNIAL HEIGHT ANSI 117.1/ 605.2 5. RECONSTRUCTION OF ENTRY LACKS PROPER DETAILING; DETAILED DEMOLITION PLANS AND STRUCTURAL FOUNDATION AND FRAMING PLANS AND DETAILS 6. CLARIFY AND NOTE REQUIRED SAFETY GLAZING IN NEW FRONT ENTRANCE VESTIBULE 7. DIMENSION ON DETAIL D-2/A-502 IS INCORRECT 8. CONFIRM THAT ALL EXISTING RAMPS COMPLY WITH ANSI 117.1 REQUIREMENTS 9. OCCUPANCY CALCULATIONS INDICATE 320 OCCUPANTS. COPY OF OCCUPANCY SIGN SHOWS 240 OCCUPANTS. IS SAMPLE SIGN INCORRECT? 10. INDICATE NEW MECHANICAL LIFT FOR HANDICAP TO BE INSTALLED ON FLOOR PLAN AND PROVIDE MANUFATURER'S SPECIFICATION AND DETAILS 11. VERIFY THAT ALL STEPS MEETS CODE REQUIREMENTS AS FOR RISER AND TREAD SIZES AND DIMENSIONS. |
11/06/2007 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | ELECTRICAL COMMENTS: ELECTRICAL PLANS DENIED FOR FOLLOWING REASONS, 1.SHEET A-201 AND 202, NOTE N16----NEW QUARTZ FLOOD LIGHTS,PROVIDE CIRCUIT DESTINATION,ALSO CANNOT LOCATE ON FIXTURE SCHEDULE. 2. SHEET E 101, PROVIDE PANEL LOCATIONS,PANEL DIRECTORIES, PANEL LOAD CALCULATIONS REGARDING CIRCUITS TO BE USED. 3. SHEET E 101 SHOW LOCATION OF DIMMER SWITCH AND CORRESPONDING CIRCUITS. 4. SHEET E P-1 LIGHT FIXTURES SHOWN AS C-2 AND C-3 NOT ON FIXTURE SCHEDULE. RAY MAJUTA ELECT PL EX DSD,520-837-4988 |
11/13/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
11/13/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The plumbing fixture schedules (sheets A-602 and EP-1) indicate a proposed hand sink for the kitchen but no hand sinks are shown on the plans. Are hand sinks part of this project? Reference Section 103.2.3, UPC 2006. 2. Provide specifications for all the proposed floor drains. Reference Section 401.1, UPC 2006. 3. Provide pressure-absorbing devices for the water connections to appliances equipped with quick-acting or solenoid valves (e.g. flush valves). Reference Section 609.10, UPC 2006. 4. Provide upper terminal cleanouts on horizontal drainage pipes exceeding 5 feet in length (horizontal drain lines serving urinals require cleanouts regardless of length). Reference Section 707.4, UPC 2006. 5. Provide a vent for each fixture trap (e.g. floor drains). Reference Sections 901.0 and 910.1, UPC 2006. 6. Provide protection of the trap seals for all floor drains subject to infrequent use. Reference Sections 1007.0 and 1007.1, UPC 2006, as amended by the City of Tucson. |
11/13/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
11/16/2007 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
11/28/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
11/28/2007 | CINDY AGUILAR | REJECT SHELF | Completed |