Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM04037
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/25/2007 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T07CM04037 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007 and the 2006 UPC with amendments on 7/10/2007. All plans should reference these codes. Adopted amendments are found at: http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html GENERAL NOTES: · Revise code references from 2003 to 2006 with appropriate paragraph references. · Provide ¼" = 1' scaled drawings with legible notation (minimum 1/8" lettering). Show new work on ¼" = 1' scaled plans. Existing references may be shown with a smaller scale of legible. · Interior alterations require the installation of smoke alarms if not existing, R313.2.1. SITE PLAN: 1. Indicate the location of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. FOUNDATION PLANS: 1. Provide a landing or floor surface at the bedroom exterior door. A landing must be at least as wide as the door it serves and 36" in the direction of travel, R311.4.3. 2. Dimension the wall thickness, as well as footing width, height, and depth into undisturbed soil for each footing type and condition (All exterior walls), R403.1.1. 3. Framed exterior walls of enclosed roof structures require continuous concrete footings of minimum 12" width and 12" below undisturbed ground surface, R403.1. Anchor treated sills with minimum ½" diameter bolts with 7" embedment, R319.1 & R403.1.6. 4. Show the 4" minimum foundation height above finished grade for masonry veneer, R404.1.6. SECTIONS - DETAILS: 1. Provide a cross-section of each exterior wall type. More than one may be required to clearly illustrate materials, sizes and connections, R106.1.1. 2. Show wood framing members resting on concrete as pressure treated, R319.1 item 2 Provide treated sill plates bearing on concrete slabs, R319.1 item 3. 3. Note and specify the size, spacing and length of anchor bolts for sill plates, R403.1.6. 4. Provide a header schedule or show sizes consistent with Table 502.5(1) & (2). Note or detail trimmers, headers and framing anchors (show sizes) at framed window openings, R802.9. 5. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c ceiling framing, IRC table R702.3.5 footnote d. 6. Provide fiber-cement board rather than moisture resistant (green) gypsum board in tub and shower areas, R702.4.2. 7. Specify #15 water-resistive barrier over studs of all exterior (wood siding) walls, R703.2. 8. Specify veneer anchoring method, weepholes, water-resistive barrier and support (ties spaced max 24" o/c horizontally & vertically and supporting max of 2.67 SQ FT), R703.2 & R703.7. 9. Show 1" air space between sheathing and veneer R703.7.4.2. 10. Provide an attic space ventilation calculation and specify size and location of all vents needed to comply, R806.2. 11. Show a minimum 1" ventilation clearance between ceiling insulation and roof sheathing if insulation is attached to truss bottom cords and eave venting is used, R806.3. This may be accomplished w/ baffles. PLUMBING PLANS: 1. The City of Tucson has adopted the 2006 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). The plans should reference this code. 2. Show the location of the water heater, UPC 301.1.1. 3. Include the dishwasher in the Water Demand Schedule and apply the lowest pressure rather than average for calculations, UPC 610.8 & Table 6-6. Consider upgrading the supply pipe size and/or meter size. MECHANICAL PLANS: 1. Show supply and return ducts with minimum R-8 insulation (includes vented attics) except when completely located inside the thermal envelope, R1103.2.1. Show R-4.2 insulation when ducts are located in an unconditioned space (chase) inside the thermal envelope, IECC 503.2.7 (City of Tucson Amended). 2. Show location of service access (size for equipment) and any catwalk/working platform for HVAC equipment located in the attic. Show the size and weight of HVAC equipment is supported by the existing truss or rafter design, M1401. 3. Provide return air duct and register sizes, M1602. Minimum duct/register size: heat pump or air conditioner - 6 SQ IN / 1000 BTU, M1403.1 (1 ton cooling = 12,000 BTU). ELECTRICAL PLANS: 1. Specify the installation recessed lighting with 3" separation from combustibles or other listed conditions, R808, and comply with energy efficiency leakage, N1102.4.3. 2. Panelboards may not be located in clothes closets or bathrooms, E3305.4. 3. At least one wall switch controlled light or outlet must be provided in the bedroom, E3803.3. OUTDOOR LIGHTING CODE 1. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. 2. Provide cut sheets for all full cut-off fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). INTERNATIONAL ENERGY CONSERVATION CODE: 1. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing and skylights is U=0.75, ceiling R=30 and walls R=13, N1102.1. 2. Show the "R" values of insulation, as well as the "U" factors of the windows and doors on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.40, N1101.2. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 10/26/2007 | GERRY KOZIOL | WWM | REVIEW | Denied | NEEDS 8TH FLOOR CREDIT EVALUATION |
| 11/06/2007 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/08/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 11/08/2007 | GERARDO BONILLA | REJECT SHELF | Completed |