Permit Review Detail
Review Status: Completed
Review Details: POST 3RD PARTY REVIEW
Permit Number - T07CM04024
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/13/2007 | DAVE MANN | FIRE | REVIEW | Denied | Minimum 1" water meter required for houses with fire sprinklers. |
| 12/13/2007 | ROBERT SHERRY | WATER | REVIEW | Denied | Tucson Water does not provide ¾" water meters; the available sizes are 5/8", 1", and 1-1/2". Contact Tucson Water to determine the appropriate meter size for this project. Include all of the water-using fixtures when determining the demand (the water fixture unit calculation on sheet 11 is incorrect). The demand is 29 GPM. |
| 12/14/2007 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 12/14/2007 | TERRY STEVENS | NPPO | REVIEW | Passed | |
| 12/14/2007 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 12/14/2007 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/14/2007 | CINDY AGUILAR | APPROVAL SHELF | Completed |
| 12/14/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |