Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM03964
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/08/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
10/08/2007 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | Impact Fee's Do Apply; Central District; 3,130 Square Feet Retail Space; $4,841.28 |
10/19/2007 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
10/25/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
10/25/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide plumbing plans with a legible background. Reference Section 103.2.3, UPC 2006. 2. Show how the temperature at the lavatory can be limited to 110 degrees Fahrenheit if the temperature control of the water heater is readily accessible to the public where they, according to the manufacturer, can "Change the desired temperature at anytime." 3. Provide the minimum plumbing facilities (i.e. a drinking fountain) required by Table 2902.1, IBC 2006, for mercantile occupancy. Deviation from this requirement requires an appeal to the building official. |
10/25/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide mechanical plans with a legible background. Reference Section 103.2.3, UPC 2006. 2. Provide information on the sequence of operation for the restroom exhaust to show that recirculation of the air from the restroom will not occur. Reference Section 403.2.1, IMC 2006. |
11/01/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T07CM03964 11/1/07 1. Plumbing specifies a 5.4 KW Water Heater. Electrical provides a circuit for a 7.2 KW WH. Please coordinate disciplines, as this has a bearing on the overcurrent protection and circuit sizing for the WH. 2. Plumbing Comment #3 calls for a drinking fountain. Provide electrical circuit as necessary. |
11/02/2007 | GERRY KOZIOL | WWM | REVIEW | Denied | OLD JOB: NEEDS TO VERIFY STATUS OF RENEWED PUBLIC SEWER CONSTRUCTION PERMIT WITH DSC 2ND FLOOR PRIOR TO ISSUANCE OF WW/DSC/1ST FLOOR HOLD HARMLESS LETTER TO CONNECT TO PRIVATE SEWER WHICH CONNECTS TO A PUBLIC SEWER WHICH HAS NOT BEEN RELEASED & ACCEPTED BY PCWWM-740-6503 |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
11/05/2007 | THAUSER1 | OUT TO CUSTOMER | Completed |
11/05/2007 | THAUSER1 | REJECT SHELF | Completed |