Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM03912
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/01/2007 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 10/01/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 10/01/2007 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 10/02/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Complete recirculation of ventilation air from toilet rooms is prohibited. Reference Section 403.2.1 (3), IMC 2006. |
| 10/02/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 10/02/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 10/02/2007 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Denied | 1) INCLUDE GAUGE OF STEEL IN DETAIL FOR HARD LID CEILING. 2) PROVIDE SUPPORT DETAILS FOR WATER HEATER OVER WOMENS RESTROOM. INCLUDE NECESSARY LIVE LOAD INFORMATION THAT MAY BE REQUIRED FOR SERVICE OF EQUIPMENT. 3) PLEASE ADD WHEEL CHAIR DUDE TO DETAIL A5/A6.1 IN THE FUTURE (KEEPS CONTRATORS FROM ARGUING WITH INSPECTORS). |
| 10/02/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 10/04/2007 | VFLORES1 | WWM | REVIEW | Needs Review | |
| 10/04/2007 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |