Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM03822
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/19/2007 | SEPTIC APPROVAL | WWM | REVIEW | Denied | SEPTIC RECORDS ARE RECERT ONLY; NEED DESIGN FROM ENGINEER ON EXSISTING SEPTIC OR NEW DESIGN |
| 11/26/2007 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Activity: T07CM03822 2nd Review Date: 11/27/07 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. I. GENERAL REQUIREMENTS: -Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. -As of June 13, 2007 the City of Tucson has adopted the 2006 IRC with the exception of the plumbing portion which has been replaced with the 2006 UPC with amendments. The plans should reference these codes, or appeal to the Building Official for 1994-design approval. II. STRUCTURAL PLANS: -Provide a complete braced wall panel layout showing panels at the ends (within 12.5') of all wall lines and additional panels centered at least every 25' between, Table R602.10.1. All exterior wall lines shall be braced and parallel interior wall lines shall be braced at intervals not exceeding 35' from exterior wall lines, R403.1.6, R602.10.1.1, R602.10.8 (interior braced wall lines needed). -Provide consistent information about the thickness of the roof sheathing (page 7). -Specify the size of all ledgers and their connection to the structure (2x what?). III. PLUMBING PLAN: -Pressure reducer required for water pressure over 80PSI. -Provide gas piping sized for the specified demand, UPC table 12-8. -Provide venting for all fixtures or show trap arms within acceptable distances from plumbing vents, UPC Table 10-1 (bathtubs). IV. ELECTRICAL PLAN: -Verify the size of the service conductors necessary for the proposed load, Table 3503.1. V. OUTDOOR LIGHTING CODE -Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. If you have any questions please contact: Clayton Trevillyan (520) 837-4913 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/11/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/11/2008 | SUE REEVES | REJECT SHELF | Completed |